LaVoce WSF051.02-16
Paramètres Thiele-Small
| Taille nominale | 5" |
|---|---|
| Impédance | 16 Ω |
| Fs | 98 Hz |
| Qts | 0.66 |
| Qes | 0.74 |
| Qms | 6.54 |
| Vas | 4.02 L |
| Sd | 86 cm² |
| Xmax | 3.2 mm |
| Re | 11.9 Ω |
| Bl | 8.27 T·m |
| Mms | 6.9 g |
| Pe | 60 W |
| Sensibilité | 90.5 dB |
Indication d'alignement
| EBP | 132 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 27.2 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| LaVoce WSF051.02 | 106 +8 | 0.6 -0.06 | 3.26 -0.76 | 3.1 -0.1 | 91.5 +1 | usable | 8 Ω vs 16 Ω: amp load changes · Xmax 3.1 mm < 3.2 mm: lower excursion-limited SPL | + |
| Sica 5 N 1.5 PL | 110.6 +12.6 | 0.56 -0.1 | 3 -1.02 | 3 -0.2 | 91 +0.5 | usable | 8 Ω vs 16 Ω: amp load changes · Xmax 3 mm < 3.2 mm: lower excursion-limited SPL | + |
| Sica 5 D 1 CS | 79 -19 | 0.52 -0.14 | 5.5 +1.48 | 3 -0.2 | 90 -0.5 | usable | 8 Ω vs 16 Ω: amp load changes · Xmax 3 mm < 3.2 mm: lower excursion-limited SPL | + |
| BMS 5S117 | 95 -3 | 0.42 -0.24 | 3.25 -0.77 | 5 +1.8 | 91 +0.5 | usable | + | |
| Eminence ALPHA 5-8 | 87 -11 | 0.54 -0.12 | 6.14 +2.12 | 5.92 +2.72 | 89.4 -1.1 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| B&C 5NDL38 | 80 -18 | 0.36 -0.3 | 4.3 +0.28 | 3.5 +0.3 | 91 +0.5 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| BMS 5N160 | 113 +15 | 0.43 -0.23 | 2.57 -1.45 | 5 +1.8 | 91 +0.5 | usable | + | |
| Faital PRO 5PR160 | 90 -8 | 0.31 -0.35 | 3.7 -0.32 | 5.1 +1.9 | 92 +1.5 | risky | 8 Ω vs 16 Ω: amp load changes | + |
| Faital PRO 5FE120 | 65 -33 | 0.48 -0.18 | 5.4 +1.38 | 5.25 +2.05 | 88 -2.5 | risky | 8 Ω vs 16 Ω: amp load changes | + |
| Faital PRO 5FE125 | 65 -33 | 0.48 -0.18 | 5.4 +1.38 | 5.25 +2.05 | 88 -2.5 | risky | 8 Ω vs 16 Ω: amp load changes | + |
Comparer les 3 plus proches avec le WSF051.02-16 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.