← tous les HP

Lavoce WAN103.00

10" · 8 Ω · 450 W · 90.7 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance8 Ω
Fs48 Hz
Qts0.35
Qes0.37
Qms4.5
Vas26 L
Sd34 cm²
Xmax9.6 mm
Re7.1 Ω
Bl19.7 T·m
Mms68.6 g
Pe450 W
Sensibilité90.7 dB

Indication d'alignement

EBP130 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 8.4 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
LaVoce WAN102.50LD52 +40.4 +0.0523.88 -2.1211.5 +1.991.5 +0.8close300 W vs 450 W: lower power handling+
Gladen SQX 1038.8 -9.20.39 +0.0424.5 -1.510 +0.487.1 -3.6usable4 Ω vs 8 Ω: amp load changes · 350 W vs 450 W: lower power handling+
Oberton 10B20048.06 +0.060.349 =31.94 +5.945.75 -3.8593 +2.3usable200 W vs 450 W: lower power handling · Xmax 5.75 mm < 9.6 mm: lower excursion-limited SPL+
Pioneer TS-W255C35 -130.351 =24.9 -1.16.6 -391 +0.3usable4 Ω vs 8 Ω: amp load changes · 350 W vs 450 W: lower power handling · Xmax 6.6 mm < 9.6 mm: lower excursion-limited SPL+
SICA 10 S 3 CP 8 Ohms48 =0.323 -0.0332.4 +6.46.1 -3.594 +3.3usableXmax 6.1 mm < 9.6 mm: lower excursion-limited SPL+
Volt B2500.1 v201439 -90.346 =26 =4.6 -589.2 -1.5usable250 W vs 450 W: lower power handling · Xmax 4.6 mm < 9.6 mm: lower excursion-limited SPL+
18 Sound 10NW75052 +40.36 +0.0138 +127.1 -2.594 +3.3usable16 Ω vs 8 Ω: amp load changes · Xmax 7.1 mm < 9.6 mm: lower excursion-limited SPL+
18 Sound 10NW75053 +50.31 -0.0434 +87.5 -2.194 +3.3usableXmax 7.5 mm < 9.6 mm: lower excursion-limited SPL+
Beyma 10MW/ND49 +10.32 -0.0340.7 +14.77.5 -2.193.5 +2.8usable6 Ω vs 8 Ω: amp load changes · 350 W vs 450 W: lower power handling · Xmax 7.5 mm < 9.6 mm: lower excursion-limited SPL+
LaVoce SSF102.50L50 +20.475 +0.1325.6 -0.45.7 -3.991.4 +0.7usableXmax 5.7 mm < 9.6 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le WAN103.00 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.