← tous les HP

LaVoce SSF082.00L

8" · 8 Ω · 350 W · 88 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale8"
Impédance8 Ω
Fs50 Hz
Qts0.44
Qes0.46
Qms9.79
Vas10.14 L
Sd220 cm²
Xmax9.2 mm
Re5.2 Ω
Bl15.65 T·m
Mms68.6 g
Pe350 W
Sensibilité88 dB

Indication d'alignement

EBP109 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 6.4 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
LaVoce SSF082.00L49 -10.41 -0.039.93 -0.2110.3 +1.187.5 -0.5close4 Ω vs 8 Ω: amp load changes+
Faital PRO 8PR20060 +100.46 +0.0216.1 +5.968.65 -0.5594 +6usable16 Ω vs 8 Ω: amp load changes · 200 W vs 350 W: lower power handling · Xmax 8.65 mm < 9.2 mm: lower excursion-limited SPL+
B&C 8BG5152 +20.4 -0.0418 +7.866.5 -2.792 +4usable250 W vs 350 W: lower power handling · Xmax 6.5 mm < 9.2 mm: lower excursion-limited SPL+
Faital PRO 8PR32065 +150.41 -0.0313.1 +2.967.33 -1.8795 +7usableXmax 7.33 mm < 9.2 mm: lower excursion-limited SPL+
B&C 8FG6453 +30.35 -0.0916.9 +6.767.5 -1.792 +4usable16 Ω vs 8 Ω: amp load changes · Xmax 7.5 mm < 9.2 mm: lower excursion-limited SPL+
B&C 8CL5169 +190.41 -0.0312.5 +2.366.5 -2.794 +6usable200 W vs 350 W: lower power handling · Xmax 6.5 mm < 9.2 mm: lower excursion-limited SPL+
LaVoce NBASS08-2055 +50.48 +0.0418.4 +8.266.5 -2.792 +4usable200 W vs 350 W: lower power handling · Xmax 6.5 mm < 9.2 mm: lower excursion-limited SPL+
B&C 8NDL5170 +200.47 +0.0313.4 +3.267 -2.294 +6usable16 Ω vs 8 Ω: amp load changes · 200 W vs 350 W: lower power handling · Xmax 7 mm < 9.2 mm: lower excursion-limited SPL+
B&C 8FG6451 +10.31 -0.1315 +4.867 -2.292 +4usableXmax 7 mm < 9.2 mm: lower excursion-limited SPL+
BMS 8S21982 +320.41 -0.039.7 -0.446.3 -2.994 +6risky250 W vs 350 W: lower power handling · Xmax 6.3 mm < 9.2 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le SSF082.00L →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.