Lautsprecher Technik MHB18 vp
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 33.8 Hz |
| Qts | 1.045 |
| Qes | 1.266 |
| Qms | 5.979 |
| Vas | 327.9 L |
| Sd | 1275.6 cm² |
| Xmax | 6.1 mm |
| Re | 6.94 Ω |
| Bl | 13.4 T·m |
| Mms | 154.4 g |
| Pe | 400 W |
| Sensibilité | 92.6 dB |
Indication d'alignement
| EBP | 27 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Selenium WPU 1805-X | 35 +1.2 | 0.7 -0.34 | 293 -34.9 | 6.3 +0.2 | 94.2 +1.6 | usable | + | |
| Raveland WHX 488 | 28 -5.8 | 0.978 -0.07 | 355 +27.1 | 4 -2.1 | 89.7 -2.9 | usable | 16 Ω vs 8 Ω: amp load changes · 150 W vs 400 W: lower power handling · Xmax 4 mm < 6.1 mm: lower excursion-limited SPL | + |
| Selenium WPU1805-X | 35 +1.2 | 0.706 -0.34 | 293 -34.9 | 6.3 +0.2 | 95.4 +2.8 | usable | + | |
| Technysound TS45/500D vp Gils | 28.2 -5.6 | 0.757 -0.29 | 341.8 +13.9 | 4 -2.1 | 91.5 -1.1 | usable | 250 W vs 400 W: lower power handling · Xmax 4 mm < 6.1 mm: lower excursion-limited SPL | + |
| Peerless FSL-1830R09-08 | 32.7 -1.1 | 0.587 -0.46 | 283.1 -44.8 | 9.6 +3.5 | 94.6 +2 | usable | + | |
| Fane 18-500 | 33 -0.8 | 0.563 -0.48 | 346 +18.1 | 6.3 +0.2 | 96.9 +4.3 | usable | + | |
| Fane SOVEREIGN 18-500 | 33 -0.8 | 0.563 -0.48 | 346 +18.1 | 6.3 +0.2 | 96.9 +4.3 | usable | + | |
| Radian 2218 | 33.8 = | 0.525 -0.52 | 286 -41.9 | 9 +2.9 | 95.5 +2.9 | risky | + | |
| Wharfedale D592 | 35 +1.2 | 0.547 -0.5 | 251 -76.9 | 6 -0.1 | 94.6 +2 | risky | 16 Ω vs 8 Ω: amp load changes · Xmax 6 mm < 6.1 mm: lower excursion-limited SPL | + |
| DAS Audio P-18 | 36 +2.2 | 0.583 -0.46 | 314 -13.9 | 4.5 -1.6 | 96.3 +3.7 | risky | Xmax 4.5 mm < 6.1 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le MHB18 vp →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.