Kenford HW-1206
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 31 Hz |
| Qts | 0.8 |
| Qes | 1 |
| Qms | 4 |
| Vas | 170 L |
| Sd | 520 cm² |
| Xmax | 3 mm |
| Re | 7.1 Ω |
| Bl | 9 T·m |
| Mms | 58.8 g |
| Pe | 100 W |
| Sensibilité | 89.5 dB |
Indication d'alignement
| EBP | 31 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Jamo 20325 | 32 +1 | 0.849 +0.05 | 163.4 -6.6 | 5 +2 | 93 +3.5 | close | 4 Ω vs 8 Ω: amp load changes | + |
| EMS LB12EX_06V | 34 +3 | 0.722 -0.08 | 200 +30 | 3 = | 90.2 +0.7 | close | 16 Ω vs 8 Ω: amp load changes · 40 W vs 100 W: lower power handling | + |
| Samy Speaker LW1200 v1 | 27.1 -3.9 | 0.754 -0.05 | 159.6 -10.4 | 4.5 +1.5 | 87 -2.5 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| Kenwood RD 30 FU 120-F | 31.6 +0.6 | 0.879 +0.08 | 206.3 +36.3 | 8 +5 | 89.8 +0.3 | usable | + | |
| Pioneer PAX30G vp1 | 36.4 +5.4 | 0.816 +0.02 | 122.3 -47.7 | 3 = | 87.8 -1.7 | usable | 16 Ω vs 8 Ω: amp load changes · 60 W vs 100 W: lower power handling | + |
| ERS HP30/100 07172 | 30 -1 | 0.588 -0.21 | 176.8 +6.8 | 2.8 -0.2 | 91.2 +1.7 | usable | Xmax 2.8 mm < 3 mm: lower excursion-limited SPL | + |
| Sony XS-NW1201 | 27.5 -3.5 | 0.928 +0.13 | 151.21 -18.79 | 4.15 +1.15 | 86.7 -2.8 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Cabasse 30BZ18 v2 | 38.5 +7.5 | 0.747 -0.05 | 154.7 -15.3 | 4 +1 | 92.8 +3.3 | usable | + | |
| Sphynx SP-W310PP | 33 +2 | 0.618 -0.18 | 182.8 +12.8 | 5 +2 | 91 +1.5 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| STX W.30.200.8.MC | 31 = | 0.622 -0.18 | 148 -22 | 6.2 +3.2 | 91.3 +1.8 | usable | + |
Comparer les 3 plus proches avec le HW-1206 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.