← tous les HP

JL Audio 13W6V2-D4

12" · 8 Ω · 500 W · 88.3 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance8 Ω
Fs24.3 Hz
Qts0.434
Qes0.464
Qms6.7
Vas111.6 L
Sd648 cm²
Xmax10.6 mm
Re6.5 Ω
Bl22 T·m
Mms226.3 g
Pe500 W
Sensibilité88.3 dB

Indication d'alignement

EBP52 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 67.5 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Ground Zero GZTW 3025 +0.70.44 +0.01110 -1.611.2 +0.690.7 +2.4close4 Ω vs 8 Ω: amp load changes+
Ground Zero GZTW 30T25 +0.70.443 +0.01110 -1.611.9 +1.390.7 +2.4close4 Ω vs 8 Ω: amp load changes+
JL Audio 12W1V2-423.68 -0.620.414 -0.02105.876 -5.729.5 -1.186.9 -1.4close4 Ω vs 8 Ω: amp load changes · 300 W vs 500 W: lower power handling · Xmax 9.5 mm < 10.6 mm: lower excursion-limited SPL+
CSS Audio TRIO12 vp22 -2.30.429 -0.0197 -14.610 -0.688.5 +0.2close300 W vs 500 W: lower power handling · Xmax 10 mm < 10.6 mm: lower excursion-limited SPL+
Infinity KAPPA PERFECT 12.123.32 -0.980.44 +0.0199.97 -11.6314.15 +3.5586.2 -2.1close4 Ω vs 8 Ω: amp load changes · 350 W vs 500 W: lower power handling+
JL Audio 12W1V2-824.98 +0.680.458 +0.02100.15 -11.459.5 -1.186.8 -1.5close300 W vs 500 W: lower power handling · Xmax 9.5 mm < 10.6 mm: lower excursion-limited SPL+
Ground Zero GZUW 300SQ25.3 +10.423 -0.0186.6 -2512.9 +2.388 -0.3close+
Focal AUDITOR RSB-30025 +0.70.466 +0.0393 -18.610.2 -0.487.4 -0.9close300 W vs 500 W: lower power handling · Xmax 10.2 mm < 10.6 mm: lower excursion-limited SPL+
Dayton Audio RSS315HFA-8 v201622.2 -2.10.444 +0.0197.2 -14.411 +0.485.8 -2.5close+
Dayton Audio DSC305-423 -1.30.408 -0.03116 +4.49.3 -1.391 +2.7close4 Ω vs 8 Ω: amp load changes · 250 W vs 500 W: lower power handling · Xmax 9.3 mm < 10.6 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 13W6V2-D4 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.