← tous les HP

JL Audio 13TW5V2-2

12" · 4 Ω · 600 W · 89.2 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance4 Ω
Fs27.6 Hz
Qts0.526
Qes0.553
Qms10.692
Vas60.3 L
Sd634 cm²
Xmax9 mm
Re3.51 Ω
Bl18.5 T·m
Mms310.4 g
Pe600 W
Sensibilité89.2 dB

Indication d'alignement

EBP50 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 74.7 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Rockford Fosgate T1D21228 +0.40.522 =55.8 -4.510.9 +1.989.1 -0.1close+
Rockford Fosgate P3D2-1226.5 -1.10.491 -0.0457.7 -2.69.5 +0.589 -0.2close+
Rockford Fosgate P3D4-1227.7 +0.10.517 -0.0157.7 -2.69.4 +0.486.3 -2.9close8 Ω vs 4 Ω: amp load changes+
Wavecor SW310WA0227.5 -0.10.52 -0.0164.5 +4.27.4 -1.689.9 +0.7close250 W vs 600 W: lower power handling · Xmax 7.4 mm < 9 mm: lower excursion-limited SPL+
Oxygen AIR2 30026.7 -0.90.452 -0.0762.9 +2.68.8 -0.289.5 +0.3close300 W vs 600 W: lower power handling · Xmax 8.8 mm < 9 mm: lower excursion-limited SPL+
MTX Audio RT12-0428 +0.40.535 +0.0168 +7.77.5 -1.590.1 +0.9close250 W vs 600 W: lower power handling · Xmax 7.5 mm < 9 mm: lower excursion-limited SPL+
Kenwood KFC-WPS1200F24.8 -2.80.544 +0.0262.685 +2.398.5 -0.591 +1.8close350 W vs 600 W: lower power handling · Xmax 8.5 mm < 9 mm: lower excursion-limited SPL+
Sound Storm Labs CR12D30.7 +3.10.522 =66.9 +6.610.3 +1.387.5 -1.7close8 Ω vs 4 Ω: amp load changes+
Wavecor SW312WA0328 +0.40.479 -0.0561 +0.77.3 -1.790.2 +1close250 W vs 600 W: lower power handling · Xmax 7.3 mm < 9 mm: lower excursion-limited SPL+
Monacor BLACKBASS-12 4 Ohms29 +1.40.482 -0.0461 +0.77.5 -1.590.1 +0.9close300 W vs 600 W: lower power handling · Xmax 7.5 mm < 9 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 13TW5V2-2 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.