JL Audio 10W3V3-2

10" · 2 Ω · 500 W · 85.37 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance2 Ω
Fs33 Hz
Qts0.495
Qes0.533
Qms7.027
Vas32.17 L
Sd345 cm²
Xmax14 mm
Re1.7 Ω
Bl8.97 T·m
Mms121.8 g
Pe500 W
Sensibilité85.37 dB

Indication d'alignement

EBP62 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 30.9 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
JL Audio 10W3V3-431.5 -1.50.485 -0.0132.23 +0.0614 =84.87 -0.5close4 Ω vs 2 Ω: amp load changes+
Brax MATRIX 10.135.8 +2.80.53 +0.0435.34 +3.1712.5 -1.586.5 +1.13close4 Ω vs 2 Ω: amp load changes · Xmax 12.5 mm < 14 mm: lower excursion-limited SPL+
JL Audio 10W6V2-D428.5 -4.50.469 -0.0333.4 +1.2311.9 -2.184.9 -0.47close8 Ω vs 2 Ω: amp load changes · Xmax 11.9 mm < 14 mm: lower excursion-limited SPL+
JL Audio 10W7AE-330.6 -2.40.537 +0.0436.1 +3.9323 +984.4 -0.97close3 Ω vs 2 Ω: amp load changes+
Audison AV 1041 +80.54 +0.0530 -2.1714 =86.8 +1.43usable4 Ω vs 2 Ω: amp load changes+
Brax BRAX MATRIX ML1035 +20.46 -0.0340 +7.8312.5 -1.587.3 +1.93usable4 Ω vs 2 Ω: amp load changes · Xmax 12.5 mm < 14 mm: lower excursion-limited SPL+
JL Audio 10W0V3-432.09 -0.910.604 +0.1131 -1.1711.4 -2.684.07 -1.3usable4 Ω vs 2 Ω: amp load changes · 300 W vs 500 W: lower power handling · Xmax 11.4 mm < 14 mm: lower excursion-limited SPL+
Boston Acoustics COMPETITOR 1000S434 +10.53 +0.0435 +2.838.5 -5.585.7 +0.33usable4 Ω vs 2 Ω: amp load changes · Xmax 8.5 mm < 14 mm: lower excursion-limited SPL+
Gladen RS-X 1035.57 +2.570.46 -0.0327.8 -4.3710 -485.9 +0.53usable4 Ω vs 2 Ω: amp load changes · 300 W vs 500 W: lower power handling · Xmax 10 mm < 14 mm: lower excursion-limited SPL+
Hertz Audio HX 25037 +40.44 -0.0524 -8.1714 =85.8 +0.43usable4 Ω vs 2 Ω: amp load changes+

Comparer les 3 plus proches avec le 10W3V3-2 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.