JL Audio 10W0-4
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 4 Ω |
| Fs | 24.2 Hz |
| Qts | 0.4 |
| Qes | 0.42 |
| Qms | 8.56 |
| Vas | 69.4039 L |
| Sd | 353 cm² |
| Xmax | 8.636 mm |
| Re | 3.86 Ω |
| Bl | 12.4 T·m |
| Mms | 110.1 g |
| Pe | 125 W |
| Sensibilité | 85.5 dB |
Indication d'alignement
| EBP | 58 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 32.7 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| JL Audio 10W0-8 | 25.6 +1.4 | 0.394 -0.01 | 69.4039 = | 8.636 = | 86.3 +0.8 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Purifi Audio PTT10.0X08-NAB-02 | 22 -2.2 | 0.393 -0.01 | 81 +11.6 | 8.9 +0.26 | 86.1 +0.6 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Image Dynamics IDQ10DQV3 | 25.5 +1.3 | 0.384 -0.02 | 71 +1.6 | 9 +0.36 | 88.9 +3.4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| AE Speakers SBP10-8 | 23.9 -0.3 | 0.47 +0.07 | 68.2 -1.2 | 14 +5.36 | 86.1 +0.6 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Phoenix Gold X MAX 10 | 23.1 -1.1 | 0.437 +0.04 | 64.5 -4.9 | 11.3 +2.66 | 88 +2.5 | close | + | |
| JL Audio 10W1V2-4 | 25.2 +1 | 0.405 +0.01 | 50.4601 -18.94 | 9.906 +1.27 | 84.6 -0.9 | close | + | |
| AE Speakers IB10AU-8 | 25 +0.8 | 0.485 +0.08 | 68 -1.4 | 15.3 +6.66 | 86.4 +0.9 | close | 8 Ω vs 4 Ω: amp load changes | + |
| JBL SB210 | 25.4 +1.2 | 0.412 +0.01 | 73 +3.6 | 7.5 -1.14 | 89.8 +4.3 | close | Xmax 7.5 mm < 8.636 mm: lower excursion-limited SPL | + |
| SEAS L26ROY-XM001-04 v2018 | 25 +0.8 | 0.417 +0.02 | 56 -13.4 | 9.7 +1.06 | 88.7 +3.2 | usable | + | |
| STX W.27.500.8.FCX | 25 +0.8 | 0.352 -0.05 | 59 -10.4 | 9.6 +0.96 | 87.6 +2.1 | usable | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 10W0-4 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.