JBL LE10A
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 30 Hz |
| Qts | 0.41 |
| Qes | 0.44 |
| Qms | 6 |
| Vas | 101.9 L |
| Sd | 316.1 cm² |
| Xmax | 6.1 mm |
| Re | 4.4 Ω |
| Bl | 8.5 T·m |
| Mms | 38.7 g |
| Pe | 60 W |
| Sensibilité | 92.5 dB |
Indication d'alignement
| EBP | 68 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 51.6 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Volt B250 | 31.7 +1.7 | 0.377 -0.03 | 104 +2.1 | 6 -0.1 | 92.8 +0.3 | close | Xmax 6 mm < 6.1 mm: lower excursion-limited SPL | + |
| SB Acoustics SB26SFCL38-4 | 27.4 -2.6 | 0.434 +0.02 | 104 +2.1 | 7.2 +1.1 | 92.4 -0.1 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Dayton Audio SD270-88 | 29.6 -0.4 | 0.44 +0.03 | 112.2 +10.3 | 6 -0.1 | 93.7 +1.2 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 6 mm < 6.1 mm: lower excursion-limited SPL | + |
| Sony XS-L100C | 28.1 -1.9 | 0.362 -0.05 | 104 +2.1 | 6.3 +0.2 | 93.4 +0.9 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Focal 11C 726 | 30.9 +0.9 | 0.378 -0.03 | 120 +18.1 | 6.9 +0.8 | 92.4 -0.1 | close | + | |
| Dayton Audio SD270A-88 DVC | 26.2 -3.8 | 0.433 +0.02 | 107.5 +5.6 | 6 -0.1 | 91.9 -0.6 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 6 mm < 6.1 mm: lower excursion-limited SPL | + |
| Focal 10N511 | 29.6 -0.4 | 0.371 -0.04 | 121 +19.1 | 6 -0.1 | 92.2 -0.3 | close | Xmax 6 mm < 6.1 mm: lower excursion-limited SPL | + |
| Beyma 10BR60 V2 vp JF rouge | 30.7 +0.7 | 0.435 +0.03 | 113.7 +11.8 | 6.5 +0.4 | 90.2 -2.3 | close | + | |
| SEAS W26FX002 | 31 +1 | 0.397 -0.01 | 87 -14.9 | 6.5 +0.4 | 90.5 -2 | close | + | |
| Usher Audio 1001B | 29 -1 | 0.387 -0.02 | 100.2 -1.7 | 5 -1.1 | 91 -1.5 | close | Xmax 5 mm < 6.1 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le LE10A →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.