JBL GTO 1002D
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 2 Ω |
| Fs | 27 Hz |
| Qts | 0.429 |
| Qes | 0.46 |
| Qms | 6.45 |
| Vas | 38.7 L |
| Sd | 355 cm² |
| Xmax | 6.3 mm |
| Re | 1 Ω |
| Bl | 7.6 T·m |
| Mms | 158.6 g |
| Pe | 250 W |
| Sensibilité | 93.2 dB |
Indication d'alignement
| EBP | 59 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 22.5 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Focal P25DB | 27.5 +0.5 | 0.431 = | 40.7 +2 | 7.5 +1.2 | 91.2 -2 | close | + | |
| Infinity 1062W 2-8 | 30.4 +3.4 | 0.426 = | 33.7 -5 | 6.5 +0.2 | 91.7 -1.5 | close | + | |
| Fusion NV-SW12 | 26.4 -0.6 | 0.438 +0.01 | 52.2 +13.5 | 7.5 +1.2 | 94.4 +1.2 | close | 1 Ω vs 2 Ω: amp load changes | + |
| Powerbass L-104D 10 | 31.5 +4.5 | 0.393 -0.04 | 35 -3.7 | 8.4 +2.1 | 93.1 -0.1 | close | + | |
| JBL GT4-10 | 29.6 +2.6 | 0.421 -0.01 | 36.1 -2.6 | 7.1 +0.8 | 88.6 -4.6 | close | 4 Ω vs 2 Ω: amp load changes | + |
| JBL STAGE 1010 | 37.1 +10.1 | 0.427 = | 41.5 +2.8 | 6.1 -0.2 | 92.1 -1.1 | usable | 4 Ω vs 2 Ω: amp load changes · Xmax 6.1 mm < 6.3 mm: lower excursion-limited SPL | + |
| Wavecor SW280WA01 | 26 -1 | 0.401 -0.03 | 43 +4.3 | 6 -0.3 | 88.1 -5.1 | usable | 4 Ω vs 2 Ω: amp load changes · Xmax 6 mm < 6.3 mm: lower excursion-limited SPL | + |
| MISCO 250-SW04D-01 | 29 +2 | 0.369 -0.06 | 39 +0.3 | 4.7 -1.6 | 92.1 -1.1 | usable | 100 W vs 250 W: lower power handling · Xmax 4.7 mm < 6.3 mm: lower excursion-limited SPL | + |
| Dayton Audio RSS265HF-4 v2012 | 26.2 -0.8 | 0.441 +0.01 | 45 +6.3 | 9.4 +3.1 | 87.8 -5.4 | usable | 4 Ω vs 2 Ω: amp load changes | + |
| Morel ULTIMO 102 | 27 = | 0.391 -0.04 | 47.4 +8.7 | 13.4 +7.1 | 90.8 -2.4 | usable | + |
Comparer les 3 plus proches avec le GTO 1002D →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.