JBL 2220J
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 16 Ω |
| Fs | 37 Hz |
| Qts | 0.174 |
| Qes | 0.18 |
| Qms | 5 |
| Vas | 297.3 L |
| Sd | 896.1 cm² |
| Xmax | 2.7 mm |
| Re | 13.2 Ω |
| Bl | 34.6 T·m |
| Mms | 70.1 g |
| Pe | 100 W |
| Sensibilité | 99 dB |
Indication d'alignement
| EBP | 206 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 19.2 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| JBL 2220H | 37 = | 0.174 = | 297.3 = | 2.7 = | 102.7 +3.7 | close | 8 Ω vs 16 Ω: amp load changes | + |
| JBL 2220B | 37 = | 0.181 +0.01 | 300 +2.7 | 2 -0.7 | 98.8 -0.2 | close | Xmax 2 mm < 2.7 mm: lower excursion-limited SPL | + |
| Yamaha JA-3882 | 38.1 +1.1 | 0.157 -0.02 | 253.1 -44.2 | 3.1 +0.4 | 99.1 +0.1 | close | + | |
| Great Plains Audio 515-8GHP GPA | 37 = | 0.187 +0.01 | 342.6 +45.3 | 2.8 +0.1 | 101.2 +2.2 | close | 75 W vs 100 W: lower power handling | + |
| JBL E140 | 32 -5 | 0.183 +0.01 | 297.3 = | 3.6 +0.9 | 100.7 +1.7 | close | 8 Ω vs 16 Ω: amp load changes | + |
| JBL E130 | 40 +3 | 0.188 +0.01 | 297.3 = | 2.5 -0.2 | 102.6 +3.6 | close | 8 Ω vs 16 Ω: amp load changes · Xmax 2.5 mm < 2.7 mm: lower excursion-limited SPL | + |
| JBL 130A | 37 = | 0.181 +0.01 | 297.3 = | 2 -0.7 | 102.4 +3.4 | close | 8 Ω vs 16 Ω: amp load changes · Xmax 2 mm < 2.7 mm: lower excursion-limited SPL | + |
| JBL 2220A | 37 = | 0.181 +0.01 | 297.3 = | 2 -0.7 | 102.4 +3.4 | close | 8 Ω vs 16 Ω: amp load changes · Xmax 2 mm < 2.7 mm: lower excursion-limited SPL | + |
| Altec 515-8GHP | 37 = | 0.187 +0.01 | 342.6 +45.3 | 2.8 +0.1 | 103 +4 | close | 8 Ω vs 16 Ω: amp load changes · 75 W vs 100 W: lower power handling | + |
| Tannoy K3808 | 35 -2 | 0.162 -0.01 | 249.2 -48.1 | 2.9 +0.2 | 101.1 +2.1 | close | 8 Ω vs 16 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 2220J →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.