Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 4 Ω |
| Fs | 48 Hz |
| Qts | 0.336 |
| Qes | 0.36 |
| Qms | 5 |
| Vas | 140.5 L |
| Sd | 880 cm² |
| Xmax | 4.9 mm |
| Re | 3.9 Ω |
| Bl | 16.7 T·m |
| Mms | 84.9 g |
| Pe | 400 W |
| Sensibilité | 101.5 dB |
Indication d'alignement
| EBP | 133 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 41 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Oberton 15XL400 | 48.78 +0.78 | 0.337 = | 140 -0.5 | 5.25 +0.35 | 102 +0.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Oberton 15LX400 | 48.8 +0.8 | 0.337 = | 140 -0.5 | 5.2 +0.3 | 100.2 -1.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Eminence KappaLITE 3015 | | 45 -3 | 0.34 = | 153 +12.5 | 5.9 +1 | 100.8 -0.7 | close | 8 Ω vs 4 Ω: amp load changes | + |
| RCF MB 15N301 | 48 = | 0.36 +0.02 | 134 -6.5 | 5.6 +0.7 | 99.2 -2.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| 18 Sound 15CX1000 | 48 = | 0.304 -0.03 | 132.5 -8 | 6 +1.1 | 100.2 -1.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| P.Audio C15-600EL | 44.9 -3.1 | 0.352 +0.02 | 137.4 -3.1 | 5 +0.1 | 99 -2.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Electro-Voice DL15X | 47.3 -0.7 | 0.337 = | 136 -4.5 | 4.1 -0.8 | 99.1 -2.4 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 4.1 mm < 4.9 mm: lower excursion-limited SPL | + |
| Eminence KAPPALITE 3015 | 45 -3 | 0.342 +0.01 | 153 +12.5 | 5.8 +0.9 | 99.7 -1.8 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Oberton 15MB35 | 47.7 -0.3 | 0.336 = | 115.1 -25.4 | 6.75 +1.85 | 100 -1.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| 18 Sound 15W1300 | 46 -2 | 0.361 +0.02 | 138 -2.5 | 6 +1.1 | 99 -2.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 2035H →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.