JBL 2032H
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 57 Hz |
| Qts | 0.541 |
| Qes | 0.6 |
| Qms | 5.5 |
| Vas | 133.1 L |
| Sd | 883.2 cm² |
| Xmax | 4.6 mm |
| Re | 4.2 Ω |
| Bl | 12.7 T·m |
| Mms | 64.1 g |
| Pe | 300 W |
| Sensibilité | 100.9 dB |
Indication d'alignement
| EBP | 95 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 187.9 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence LEGEND CA154 | 51.1 -5.9 | 0.487 -0.05 | 108.2 -24.9 | 4.5 -0.1 | 100.6 -0.3 | usable | 4 Ω vs 8 Ω: amp load changes · Xmax 4.5 mm < 4.6 mm: lower excursion-limited SPL | + |
| Celestion TF1525E 4 Ohms | 49.8 -7.2 | 0.493 -0.05 | 128.2 -4.9 | 3.5 -1.1 | 100.7 -0.2 | usable | 4 Ω vs 8 Ω: amp load changes · Xmax 3.5 mm < 4.6 mm: lower excursion-limited SPL | + |
| Celestion BL15-400X | 54.2 -2.8 | 0.592 +0.05 | 110.9 -22.2 | 4.8 +0.2 | 97.3 -3.6 | usable | + | |
| RCF L 17/64AF | 51 -6 | 0.468 -0.07 | 130 -3.1 | 4 -0.6 | 98.8 -2.1 | usable | 150 W vs 300 W: lower power handling · Xmax 4 mm < 4.6 mm: lower excursion-limited SPL | + |
| RCF MB 15X301 (prodance) | 50.6 -6.4 | 0.44 -0.1 | 133.8 +0.7 | 5.9 +1.3 | 99.2 -1.7 | usable | + | |
| LaVoce WSF152.50 | 46 -11 | 0.505 -0.04 | 137 +3.9 | 4.7 +0.1 | 97.3 -3.6 | usable | + | |
| Focal 38KXSPL | 45.8 -11.2 | 0.55 +0.01 | 116.4 -16.7 | 5.5 +0.9 | 98 -2.9 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| SICA P-A-PL15B3S | 46.5 -10.5 | 0.479 -0.06 | 139.8 +6.7 | 5.5 +0.9 | 98.3 -2.6 | usable | + | |
| DAP Audio AB-15 | 46.7 -10.3 | 0.546 +0.01 | 122.3 -10.8 | 5.5 +0.9 | 95.4 -5.5 | usable | + | |
| 18 Sound 15W500 | 50 -7 | 0.52 -0.02 | 189 +55.9 | 4 -0.6 | 100.5 -0.4 | usable | Xmax 4 mm < 4.6 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 2032H →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.