JBL 1800 GTI

18" · 4 Ω · 600 W · 100.3 dB

Paramètres Thiele-Small

Taille nominale18"
Impédance4 Ω
Fs30 Hz
Qts0.431
Qes0.46
Qms6.77
Vas362.6 L
Sd1270 cm²
Xmax9.6 mm
Re2.5 Ω
Bl13.4 T·m
Mms175.5 g
Pe600 W
Sensibilité100.3 dB

Indication d'alignement

EBP65 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 214.3 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
McCauley 6152-830 =0.434 =354 -8.612 +2.497.1 -3.2close8 Ω vs 4 Ω: amp load changes+
Peerless FSL-1830R09-0427.8 -2.20.427 =356 -6.68.5 -1.197.8 -2.5close400 W vs 600 W: lower power handling · Xmax 8.5 mm < 9.6 mm: lower excursion-limited SPL+
SB Audience BIANCO-18SW450 v202428 -20.445 +0.01370.4 +7.89.1 -0.596.4 -3.9close8 Ω vs 4 Ω: amp load changes · 450 W vs 600 W: lower power handling · Xmax 9.1 mm < 9.6 mm: lower excursion-limited SPL+
Beyma 18WRS60030 =0.47 +0.04354 -8.68.5 -1.197 -3.3close8 Ω vs 4 Ω: amp load changes · Xmax 8.5 mm < 9.6 mm: lower excursion-limited SPL+
Eminence KILOMAX PRO 18 A v201632 +20.467 +0.04331.5 -31.110 +0.497.4 -2.9close8 Ω vs 4 Ω: amp load changes+
Faital PRO 18FH500 v201630 =0.35 -0.08374.8 +12.29.2 -0.498.4 -1.9close8 Ω vs 4 Ω: amp load changes · Xmax 9.2 mm < 9.6 mm: lower excursion-limited SPL+
SB Audience ROSSO-18SW65031 +10.418 -0.01304.3 -58.39 -0.697.2 -3.1close8 Ω vs 4 Ω: amp load changes · Xmax 9 mm < 9.6 mm: lower excursion-limited SPL+
Beyma 18LX60 vp131.3 +1.30.472 +0.04385 +22.49 -0.696.8 -3.5close8 Ω vs 4 Ω: amp load changes · Xmax 9 mm < 9.6 mm: lower excursion-limited SPL+
Beyma 18LX60 (prodance)31.3 +1.30.472 +0.04385.3 +22.79 -0.696.8 -3.5close8 Ω vs 4 Ω: amp load changes · Xmax 9 mm < 9.6 mm: lower excursion-limited SPL+
Selenium 18SWS110034 +40.447 +0.02316 -46.69.3 -0.397.8 -2.5close8 Ω vs 4 Ω: amp load changes · Xmax 9.3 mm < 9.6 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 1800 GTI →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.