JBL 1000GTI
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 4 Ω |
| Fs | 62 Hz |
| Qts | 0.64 |
| Qes | 0.73 |
| Qms | 5.44 |
| Vas | 19 L |
| Sd | 345 cm² |
| Xmax | 5.97 mm |
| Re | 3.2 Ω |
| Bl | 10.04 T·m |
| Mms | 58.68 g |
| Pe | 300 W |
| Sensibilité | 86 dB |
Indication d'alignement
| EBP | 85 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 86.1 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Fusion PF-SW100D4 | 45.3 -16.7 | 0.642 = | 19.3 +0.3 | 5.8 -0.17 | 88.1 +2.1 | usable | 8 Ω vs 4 Ω: amp load changes · Xmax 5.8 mm < 5.97 mm: lower excursion-limited SPL | + |
| Sony XS-GTR101L | 44 -18 | 0.72 +0.08 | 21 +2 | 6.9 +0.93 | 85.4 -0.6 | usable | + | |
| Skar Audio EV-10 S2 | 47.5 -14.5 | 0.69 +0.05 | 15.2 -3.8 | 8.5 +2.53 | 85.1 -0.9 | usable | 2 Ω vs 4 Ω: amp load changes · 150 W vs 300 W: lower power handling | + |
| Auditor 250 S | 42.1 -19.9 | 0.631 -0.01 | 20.5 +1.5 | 5 -0.97 | 89 +3 | usable | Xmax 5 mm < 5.97 mm: lower excursion-limited SPL | + |
| Sony XS-L104P5B | 37.7 -24.3 | 0.569 -0.07 | 19.3 +0.3 | 6 +0.03 | 87.8 +1.8 | usable | + | |
| Skar Audio EV-10 S4 | 50.9 -11.1 | 0.76 +0.12 | 14 -5 | 8.5 +2.53 | 85.2 -0.8 | usable | 150 W vs 300 W: lower power handling | + |
| Focal SUB P25 | 48 -14 | 0.621 -0.02 | 16 -3 | 4.1 -1.87 | 89.4 +3.4 | usable | Xmax 4.1 mm < 5.97 mm: lower excursion-limited SPL | + |
| Focal 27 V2 | 38.5 -23.5 | 0.629 -0.01 | 21.3 +2.3 | 5.5 -0.47 | 90.1 +4.1 | usable | Xmax 5.5 mm < 5.97 mm: lower excursion-limited SPL | + |
| HiVi SP10 | 34 -28 | 0.573 -0.07 | 17.1 -1.9 | 6.7 +0.73 | 85.8 -0.2 | usable | + | |
| Kenwood KFC-XW100F | 38.6 -23.4 | 0.72 +0.08 | 21.05 +2.05 | 7.5 +1.53 | 83.4 -2.6 | usable | + |
Comparer les 3 plus proches avec le 1000GTI →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.