Isophon PSL 300/50
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 40.3 Hz |
| Qts | 0.582 |
| Qes | 0.672 |
| Qms | 4.367 |
| Vas | 71.7 L |
| Sd | 518.7 cm² |
| Xmax | 2.8 mm |
| Re | 2.7 Ω |
| Bl | 9.1 T·m |
| Mms | 82 g |
| Pe | 50 W |
| Sensibilité | 95.1 dB |
Indication d'alignement
| EBP | 60 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 150.6 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Pioneer TS-W1RS | 40.2 -0.1 | 0.516 -0.07 | 75.5 +3.8 | 4.2 +1.4 | 95.5 +0.4 | close | + | |
| Audax HT300G0 | 36.8 -3.5 | 0.531 -0.05 | 77.7 +6 | 6.6 +3.8 | 94.4 -0.7 | usable | + | |
| Supravox T285HF64 | 55 +14.7 | 0.6 +0.02 | 74.6 +2.9 | 3.3 +0.5 | 95.6 +0.5 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Siare 31TE vp 1 | 43.8 +3.5 | 0.545 -0.04 | 91.5 +19.8 | 4.5 +1.7 | 95.5 +0.4 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Skytronic 902.436 | 42 +1.7 | 0.6 +0.02 | 65 -6.7 | 4 +1.2 | 89.8 -5.3 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Elder Audio 12LB075-UMOD | 40 -0.3 | 0.472 -0.11 | 73 +1.3 | 5.5 +2.7 | 93.1 -2 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio 310-8 | 44.4 +4.1 | 0.482 -0.1 | 81.9 +10.2 | 3.5 +0.7 | 94.9 -0.2 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| B&C 12 CLX 64 | 54 +13.7 | 0.575 -0.01 | 74 +2.3 | 5.3 +2.5 | 96.3 +1.2 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Conrad CPA 15-300 | 43 +2.7 | 0.559 -0.02 | 100.5 +28.8 | 4 +1.2 | 93.8 -1.3 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Monacor CRB-12TC vp parallèle | 31 -9.3 | 0.611 +0.03 | 75 +3.3 | 4.9 +2.1 | 93.5 -1.6 | usable | 2 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le PSL 300/50 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.