Infinity BETA15
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 4 Ω |
| Fs | 24.4 Hz |
| Qts | 0.23 |
| Qes | 0.24 |
| Qms | 5.82 |
| Vas | 289.9 L |
| Sd | 829 cm² |
| Xmax | 7.9 mm |
| Re | 3.4 Ω |
| Bl | 17.5 T·m |
| Mms | 141.5 g |
| Pe | 350 W |
| Sensibilité | 98.1 dB |
Indication d'alignement
| EBP | 102 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 34.3 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Beyma SM115/K vp1 | 27.6 +3.2 | 0.222 -0.01 | 296.7 +6.8 | 8 +0.1 | 98.3 +0.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Beyma SM115/K vp2 | 29.8 +5.4 | 0.228 = | 291 +1.1 | 8 +0.1 | 99 +0.9 | close | 8 Ω vs 4 Ω: amp load changes | + |
| STX W.38.800.4.MC | 27 +2.6 | 0.219 -0.01 | 272 -17.9 | 8 +0.1 | 99.9 +1.8 | close | + | |
| Magnat SUB 400 SUPREME | 21 -3.4 | 0.228 = | 330 +40.1 | 9.5 +1.6 | 96.7 -1.4 | close | + | |
| Beyma SM115/K | 29 +4.6 | 0.249 +0.02 | 273 -16.9 | 8 +0.1 | 97.2 -0.9 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Beyma SM-115/K | 27 +2.6 | 0.253 +0.02 | 345 +55.1 | 8 +0.1 | 97.5 -0.6 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio APOLLO 15LF | 25.5 +1.1 | 0.26 +0.03 | 331 +41.1 | 9.3 +1.4 | 96 -2.1 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio 15LF ODEUM | 25.5 +1.1 | 0.26 +0.03 | 331.3 +41.4 | 9.3 +1.4 | 96 -2.1 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| STX W.38.800.8.MC | 28 +3.6 | 0.252 +0.02 | 247 -42.9 | 8 +0.1 | 96.5 -1.6 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Beyma 15BR400 | 30 +5.6 | 0.236 +0.01 | 274 -15.9 | 6 -1.9 | 98.3 +0.2 | usable | 8 Ω vs 4 Ω: amp load changes · Xmax 6 mm < 7.9 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le BETA15 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.