Helix W-12 COMPETITION
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 21.4 Hz |
| Qts | 0.3 |
| Qes | 0.33 |
| Qms | 3.6 |
| Vas | 118.6 L |
| Sd | 519 cm² |
| Xmax | 11 mm |
| Re | 3.2 Ω |
| Bl | 15.1 T·m |
| Mms | 174.9 g |
| Pe | 350 W |
| Sensibilité | 87.3 dB |
Indication d'alignement
| EBP | 65 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 26 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Kenwood XR-W1204 | 21.5 +0.1 | 0.341 +0.04 | 125.386 +6.79 | 10.8 -0.2 | 87.3 = | close | Xmax 10.8 mm < 11 mm: lower excursion-limited SPL | + |
| Helix P12 | 21.4 = | 0.302 = | 118.6 = | 9.9 -1.1 | 91.4 +4.1 | close | Xmax 9.9 mm < 11 mm: lower excursion-limited SPL | + |
| Visaton TIW 360X | 21 -0.4 | 0.34 +0.04 | 140 +21.4 | 12.5 +1.5 | 87.3 = | close | 8 Ω vs 4 Ω: amp load changes | + |
| Eminence LAB 12C | 23 +1.6 | 0.33 +0.03 | 128.31 +9.71 | 13 +2 | 88.9 +1.6 | close | + | |
| Visaton TIW360X | 21 -0.4 | 0.336 +0.04 | 140 +21.4 | 12.2 +1.2 | 88.8 +1.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Pioneer TS-W 304 C | 21 -0.4 | 0.307 +0.01 | 136 +17.4 | 11 = | 92.2 +4.9 | close | + | |
| Pioneer TS-W1201C | 20 -1.4 | 0.291 -0.01 | 118 -0.6 | 9.2 -1.8 | 91.2 +3.9 | close | Xmax 9.2 mm < 11 mm: lower excursion-limited SPL | + |
| Ground Zero GZHW 30X | 22.6 +1.2 | 0.32 +0.02 | 101 -17.6 | 12.3 +1.3 | 90.6 +3.3 | usable | + | |
| Eminence LAB 12 | | 22 +0.6 | 0.38 +0.08 | 125.2 +6.6 | 13 +2 | 89.2 +1.9 | usable | 6 Ω vs 4 Ω: amp load changes | + |
| Eminence LAB 12 | 22 +0.6 | 0.379 +0.08 | 125.2 +6.6 | 11 = | 90 +2.7 | usable | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le W-12 COMPETITION →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.