← tous les HP

Goldwood GW-10PC/4

10" · 4 Ω · 200 W · 92.9 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance4 Ω
Fs43.1 Hz
Qts0.404
Qes0.446
Qms4.252
Vas32.7 L
Sd344.9 cm²
Xmax4.8 mm
Re3.8 Ω
Bl12.7 T·m
Mms69.5 g
Pe200 W
Sensibilité92.9 dB

Indication d'alignement

EBP97 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 15.8 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Clarion SRM259143 -0.10.398 -0.0131.1 -1.63.5 -1.393.1 +0.2close150 W vs 200 W: lower power handling · Xmax 3.5 mm < 4.8 mm: lower excursion-limited SPL+
Oberton 10B20048.06 +4.960.349 -0.0631.94 -0.765.75 +0.9593 +0.1close8 Ω vs 4 Ω: amp load changes+
PHL Audio 300245 +1.90.357 -0.0535 +2.34 -0.892.9 =close8 Ω vs 4 Ω: amp load changes · Xmax 4 mm < 4.8 mm: lower excursion-limited SPL+
Oberton 10B10044 +0.90.447 +0.0440.5 +7.84.4 -0.492.5 -0.4close8 Ω vs 4 Ω: amp load changes · 100 W vs 200 W: lower power handling · Xmax 4.4 mm < 4.8 mm: lower excursion-limited SPL+
Zeuz 10500X48.4 +5.30.445 +0.0434.6 +1.94.3 -0.594.5 +1.6usableXmax 4.3 mm < 4.8 mm: lower excursion-limited SPL+
Focal 27 H46.6 +3.50.499 +0.0930.4 -2.35 +0.293.7 +0.8usable+
McCauley 622240 -3.10.39 -0.0141.9 +9.27 +2.291.5 -1.4usable8 Ω vs 4 Ω: amp load changes+
PHL Audio 3002 v201048.6 +5.50.436 +0.0329 -3.74 -0.892.3 -0.6usable8 Ω vs 4 Ω: amp load changes · Xmax 4 mm < 4.8 mm: lower excursion-limited SPL+
Focal 10W 641143.7 +0.60.451 +0.0542.3 +9.64.2 -0.692.6 -0.3usable8 Ω vs 4 Ω: amp load changes · 100 W vs 200 W: lower power handling · Xmax 4.2 mm < 4.8 mm: lower excursion-limited SPL+
Focal 10V 641250 +6.90.423 +0.0232.8 +0.13.3 -1.593.4 +0.5usable8 Ω vs 4 Ω: amp load changes · 100 W vs 200 W: lower power handling · Xmax 3.3 mm < 4.8 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le GW-10PC/4 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.