← tous les HP

Gauss 3540 GAUSS

15" · 4 Ω · 200 W · 101.8 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale15"
Impédance4 Ω
Fs25 Hz
Qts0.16
Qes0.17
Qms2.7
Vas438.9 L
Sd890 cm²
Xmax5.1 mm
Re3.4 Ω
Bl17.9 T·m
Mms102.5 g
Pe200 W
Sensibilité101.8 dB

Indication d'alignement

EBP147 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 23.7 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Gauss 3580 GAUSS25 =0.16 =438.9 =5.1 =99.2 -2.6close8 Ω vs 4 Ω: amp load changes+
Audax PR380M223.8 -1.20.151 -0.01376 -62.95.5 +0.498.1 -3.7usable8 Ω vs 4 Ω: amp load changes+
Audax PR38S10024 -10.171 +0.01423 -15.94 -1.198.7 -3.1usable8 Ω vs 4 Ω: amp load changes · Xmax 4 mm < 5.1 mm: lower excursion-limited SPL+
Supravox 400-2000EXC_15V25 =0.196 +0.04429 -9.94.9 -0.298.1 -3.7usable8 Ω vs 4 Ω: amp load changes · 120 W vs 200 W: lower power handling · Xmax 4.9 mm < 5.1 mm: lower excursion-limited SPL+
Fluxmag 1504-BM22.7 -2.30.183 +0.02469.9 +315 -0.198 -3.8usable8 Ω vs 4 Ω: amp load changes · Xmax 5 mm < 5.1 mm: lower excursion-limited SPL+
Audax PR380M2 v200925 =0.191 +0.03380 -58.95.5 +0.498.2 -3.6usable8 Ω vs 4 Ω: amp load changes+
Fluxmag 1504-CX25.2 +0.20.158 =659.1 +220.24 -1.1101.1 -0.7usable8 Ω vs 4 Ω: amp load changes · Xmax 4 mm < 5.1 mm: lower excursion-limited SPL+
Supravox 400-2000EXC_14V25 =0.214 +0.05439 +0.15 -0.197.8 -4usable8 Ω vs 4 Ω: amp load changes · 120 W vs 200 W: lower power handling · Xmax 5 mm < 5.1 mm: lower excursion-limited SPL+
Beyma 15B4224.2 -0.80.185 +0.02480.9 +424 -1.198.8 -3usable8 Ω vs 4 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 4 mm < 5.1 mm: lower excursion-limited SPL+
Altec 904-8A30.5 +5.50.164 =401.5 -37.43.3 -1.8101.9 +0.1usable8 Ω vs 4 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 3.3 mm < 5.1 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 3540 GAUSS →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.