Focal AUDITOR RSB-300
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 25 Hz |
| Qts | 0.466 |
| Qes | 0.52 |
| Qms | 4.5 |
| Vas | 93 L |
| Sd | 471 cm² |
| Xmax | 10.2 mm |
| Re | 6.4 Ω |
| Bl | 16.2 T·m |
| Mms | 135.5 g |
| Pe | 300 W |
| Sensibilité | 87.4 dB |
Indication d'alignement
| EBP | 48 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 71.4 L |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| JL Audio 12W1V2-8 | 24.98 -0.02 | 0.458 -0.01 | 100.15 +7.15 | 9.5 -0.7 | 86.8 -0.6 | close | Xmax 9.5 mm < 10.2 mm: lower excursion-limited SPL | + |
| Infinity REFERENCE 1240W | 25.4 +0.4 | 0.47 = | 84.4 -8.6 | 11.5 +1.3 | 86.3 -1.1 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Infinity REFERENCE 1250W | 25.4 +0.4 | 0.47 = | 84.4 -8.6 | 11.5 +1.3 | 86.3 -1.1 | close | 4 Ω vs 8 Ω: amp load changes | + |
| JL Audio 12W6V2-D4 | 25 = | 0.45 -0.02 | 79.9 -13.1 | 12.7 +2.5 | 86.9 -0.5 | close | + | |
| Dayton Audio RSS315HF-4 | 25 = | 0.489 +0.02 | 85.1 -7.9 | 10.1 -0.1 | 89.4 +2 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 10.1 mm < 10.2 mm: lower excursion-limited SPL | + |
| Ground Zero GZUW 300SQ | 25.3 +0.3 | 0.423 -0.04 | 86.6 -6.4 | 12.9 +2.7 | 88 +0.6 | close | + | |
| Dayton Audio RSS315HFA-8 v2016 | 22.2 -2.8 | 0.444 -0.02 | 97.2 +4.2 | 11 +0.8 | 85.8 -1.6 | close | + | |
| Infinity KAPPA PERFECT 12.1 | 23.32 -1.68 | 0.44 -0.03 | 99.97 +6.97 | 14.15 +3.95 | 86.2 -1.2 | close | 4 Ω vs 8 Ω: amp load changes | + |
| JL Audio 13W6V2-D4 | 24.3 -0.7 | 0.434 -0.03 | 111.6 +18.6 | 10.6 +0.4 | 88.3 +0.9 | close | + | |
| CSS Audio TRIO12 vp | 22 -3 | 0.429 -0.04 | 97 +4 | 10 -0.2 | 88.5 +1.1 | close | Xmax 10 mm < 10.2 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le AUDITOR RSB-300 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.