Focal 11C 726
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 30.9 Hz |
| Qts | 0.378 |
| Qes | 0.44 |
| Qms | 2.67 |
| Vas | 120 L |
| Sd | 359.7 cm² |
| Xmax | 6.9 mm |
| Re | 5.79 Ω |
| Bl | 10.1 T·m |
| Mms | 40.1 g |
| Pe | 100 W |
| Sensibilité | 92.4 dB |
Indication d'alignement
| EBP | 70 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 48 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Focal 10V 6411 | 32.9 +2 | 0.378 = | 116.9 -3.1 | 7 +0.1 | 93.4 +1 | close | + | |
| Focal 10N511 | 29.6 -1.3 | 0.371 -0.01 | 121 +1 | 6 -0.9 | 92.2 -0.2 | close | 60 W vs 100 W: lower power handling · Xmax 6 mm < 6.9 mm: lower excursion-limited SPL | + |
| Visaton W250S | 31 +0.1 | 0.401 +0.02 | 140 +20 | 7 +0.1 | 92.2 -0.2 | close | + | |
| Visaton W250S-8 | 31 +0.1 | 0.323 -0.05 | 121 +1 | 6.5 -0.4 | 92.5 +0.1 | close | Xmax 6.5 mm < 6.9 mm: lower excursion-limited SPL | + |
| Visaton W250S v2 | 31 +0.1 | 0.323 -0.05 | 121 +1 | 6.5 -0.4 | 92.5 +0.1 | close | Xmax 6.5 mm < 6.9 mm: lower excursion-limited SPL | + |
| Visaton W250S8 | 31 +0.1 | 0.323 -0.05 | 121 +1 | 6.5 -0.4 | 92.5 +0.1 | close | Xmax 6.5 mm < 6.9 mm: lower excursion-limited SPL | + |
| Visaton W250S8 v2 | 31 +0.1 | 0.323 -0.05 | 121 +1 | 6.5 -0.4 | 92.5 +0.1 | close | Xmax 6.5 mm < 6.9 mm: lower excursion-limited SPL | + |
| Volt B250 | 31.7 +0.8 | 0.377 = | 104 -16 | 6 -0.9 | 92.8 +0.4 | close | Xmax 6 mm < 6.9 mm: lower excursion-limited SPL | + |
| SEAS CA26RFX | 29 -1.9 | 0.337 -0.04 | 129 +9 | 7 +0.1 | 92 -0.4 | close | + | |
| Beyma 10"BR60 V2 | 29 -1.9 | 0.39 +0.01 | 142 +22 | 6.5 -0.4 | 92 -0.4 | close | Xmax 6.5 mm < 6.9 mm: lower excursion-limited SPL | + |