← tous les HP

Focal 10WM

10" · 8 Ω · 400 W · 85.4 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance8 Ω
Fs31 Hz
Qts0.683
Qes0.76
Qms6.7
Vas28 L
Sd327 cm²
Xmax9.2 mm
Re4 Ω
Bl12 T·m
Mms141.1 g
Pe400 W
Sensibilité85.4 dB

Indication d'alignement

EBP41 · sealed
Sealed Vb (Qtc ≈ 0.71)≈ 389.8 L

EBP < 50 : favorise un alignement clos.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Focal SUB10WM31 =0.683 =28 =8.5 -0.786.5 +1.1close4 Ω vs 8 Ω: amp load changes · Xmax 8.5 mm < 9.2 mm: lower excursion-limited SPL+
Alpine SWE-104233 +20.66 -0.0233 +511.7 +2.584.1 -1.3close4 Ω vs 8 Ω: amp load changes · 250 W vs 400 W: lower power handling+
Hertz Audio DS 250.336 +50.62 -0.0629 +110 +0.884.8 -0.6close4 Ω vs 8 Ω: amp load changes · 200 W vs 400 W: lower power handling+
JL Audio 10W0V3-432.09 +1.090.604 -0.0831 +311.4 +2.284.07 -1.33close4 Ω vs 8 Ω: amp load changes · 300 W vs 400 W: lower power handling+
JL Audio 10W0V3-432.1 +1.10.604 -0.0831 +38.7 -0.586.7 +1.3close300 W vs 400 W: lower power handling · Xmax 8.7 mm < 9.2 mm: lower excursion-limited SPL+
HiVi CS100B31 =0.653 -0.0334.2 +6.27 -2.286.8 +1.4usable4 Ω vs 8 Ω: amp load changes · 200 W vs 400 W: lower power handling · Xmax 7 mm < 9.2 mm: lower excursion-limited SPL+
Earthquake Sound DB-1026 -50.7 +0.0230.5 +2.519.1 +9.987 +1.6usable4 Ω vs 8 Ω: amp load changes+
hertz Hertz Audio ML2500.333 +20.598 -0.0923.5 -4.510.3 +1.187.8 +2.4usable4 Ω vs 8 Ω: amp load changes+
Polk Audio DB104035 +40.55 -0.1328.3 +0.37.5 -1.785 -0.4usable4 Ω vs 8 Ω: amp load changes · 270 W vs 400 W: lower power handling · Xmax 7.5 mm < 9.2 mm: lower excursion-limited SPL+
American Bass SL 10433.6 +2.60.52 -0.1626.8 -1.28.5 -0.784.3 -1.1usable4 Ω vs 8 Ω: amp load changes · 250 W vs 400 W: lower power handling · Xmax 8.5 mm < 9.2 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 10WM →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.