Fane SOVEREIGN PRO 10-300
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 58 Hz |
| Qts | 0.322 |
| Qes | 0.34 |
| Qms | 6.08 |
| Vas | 41 L |
| Sd | 378 cm² |
| Xmax | 4.7 mm |
| Re | 5.7 Ω |
| Bl | 15 T·m |
| Mms | 36.8 g |
| Pe | 300 W |
| Sensibilité | 97.2 dB |
Indication d'alignement
| EBP | 171 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 10.7 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Fane SOVEREIGN 10-300 | 58 = | 0.313 -0.01 | 43 +2 | 4.8 +0.1 | 97.5 +0.3 | close | + | |
| RCF MB 10N251 (prodance) | 58.9 +0.9 | 0.33 +0.01 | 38.8 -2.2 | 4.8 +0.1 | 97.3 +0.1 | close | + | |
| Faital PRO 10PR310 | 55 -3 | 0.31 -0.01 | 40.3 -0.7 | 4.92 +0.22 | 97 -0.2 | close | 4 Ω vs 8 Ω: amp load changes | + |
| SB Audience BIANCO-10MW200 | 58 = | 0.336 +0.01 | 39.3 -1.7 | 5.2 +0.5 | 96.2 -1 | close | + | |
| Fane SOVEREIGN 10-275 | 60 +2 | 0.343 +0.02 | 42.4 +1.4 | 5 +0.3 | 97.5 +0.3 | close | + | |
| PHL Audio 3020 | 60 +2 | 0.337 +0.02 | 41 = | 4.1 -0.6 | 97.6 +0.4 | close | 200 W vs 300 W: lower power handling · Xmax 4.1 mm < 4.7 mm: lower excursion-limited SPL | + |
| SICA 10 N 2.5 PL v2017 | 57 -1 | 0.357 +0.03 | 40.9 -0.1 | 4.5 -0.2 | 96.5 -0.7 | close | Xmax 4.5 mm < 4.7 mm: lower excursion-limited SPL | + |
| Sica 10 N 2.5 PL | 57 -1 | 0.36 +0.04 | 40.9 -0.1 | 4.5 -0.2 | 96.6 -0.6 | close | Xmax 4.5 mm < 4.7 mm: lower excursion-limited SPL | + |
| Volt BM251.3 PA | 55 -3 | 0.346 +0.02 | 44 +3 | 4.8 +0.1 | 96.8 -0.4 | close | 200 W vs 300 W: lower power handling | + |
| B&C 10NDL64 | 58 = | 0.3 -0.02 | 34.5 -6.5 | 4.5 -0.2 | 97 -0.2 | close | 16 Ω vs 8 Ω: amp load changes · Xmax 4.5 mm < 4.7 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le SOVEREIGN PRO 10-300 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.