Fane COLOSSUS PRIME 18XS
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 33 Hz |
| Qts | 0.385 |
| Qes | 0.404 |
| Qms | 8.2 |
| Vas | 257 L |
| Sd | 1209 cm² |
| Xmax | 12 mm |
| Re | 5.2 Ω |
| Bl | 22.4 T·m |
| Mms | 188 g |
| Pe | 1200 W |
| Sensibilité | 95.4 dB |
Indication d'alignement
| EBP | 82 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 108.3 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Faital PRO 18FX800 | 34 +1 | 0.4 +0.02 | 247 -10 | 13.8 +1.8 | 96 +0.6 | close | + | |
| Beyma 18LEX1000Nd | 34 +1 | 0.39 +0.01 | 260 +3 | 11 -1 | 98 +2.6 | close | Xmax 11 mm < 12 mm: lower excursion-limited SPL | + |
| Beyma 18LEX1000Fe | 34 +1 | 0.38 -0.01 | 250 -7 | 11 -1 | 98 +2.6 | close | Xmax 11 mm < 12 mm: lower excursion-limited SPL | + |
| Beyma 18LEX1200FE | 32 -1 | 0.378 -0.01 | 277 +20 | 11 -1 | 97.4 +2 | close | Xmax 11 mm < 12 mm: lower excursion-limited SPL | + |
| Beyma 18"LEX1600Nd | 33 = | 0.43 +0.04 | 231 -26 | 14.5 +2.5 | 96 +0.6 | close | + | |
| Dayton Audio APOLLO 18F | 32 -1 | 0.401 +0.02 | 287.7 +30.7 | 10.6 -1.4 | 96.4 +1 | close | Xmax 10.6 mm < 12 mm: lower excursion-limited SPL | + |
| Beyma 18LEX1000/Nd | 34 +1 | 0.391 +0.01 | 260 +3 | 9.4 -2.6 | 97.8 +2.4 | close | Xmax 9.4 mm < 12 mm: lower excursion-limited SPL | + |
| Fane SOVEREIGN PRO 18-800 P | 33 = | 0.386 = | 258 +1 | 7.5 -4.5 | 96.4 +1 | close | 800 W vs 1200 W: lower power handling · Xmax 7.5 mm < 12 mm: lower excursion-limited SPL | + |
| Faital PRO 18HW1070 | 32 -1 | 0.38 -0.01 | 195.9 -61.1 | 13 +1 | 97 +1.6 | close | + | |
| BMS 18N850vv2 | 29.8 -3.2 | 0.33 -0.05 | 243 -14 | 12 = | 95 -0.4 | close | + |
Comparer les 3 plus proches avec le COLOSSUS PRIME 18XS →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.