Faital PRO 6RS140

6" · 16 Ω · 200 W · 92 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale6"
Impédance16 Ω
Fs65 Hz
Qts0.36
Qes0.38
Qms6
Vas9.9 L
Sd133 cm²
Xmax5.5 mm
Re12.6 Ω
Mms15 g
Pe200 W
Sensibilité92 dB

Indication d'alignement

EBP171 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 3.5 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
LaVoce WAN061.80-1662 -30.31 -0.0510.26 +0.365.2 -0.392.5 +0.5closeXmax 5.2 mm < 5.5 mm: lower excursion-limited SPL+
Sica 6 NR 2 PL60.5 -4.50.33 -0.039.4 -0.54 -1.591.4 -0.6usable8 Ω vs 16 Ω: amp load changes · Xmax 4 mm < 5.5 mm: lower excursion-limited SPL+
Faital PRO 6RS14065 =0.27 -0.099.3 -0.65.6 +0.193 +1usable8 Ω vs 16 Ω: amp load changes+
Sica 6 N 2 PL68 +30.33 -0.038.7 -1.23.5 -292.3 +0.3usable8 Ω vs 16 Ω: amp load changes · Xmax 3.5 mm < 5.5 mm: lower excursion-limited SPL+
LaVoce WAF061.8065 =0.42 +0.067.26 -2.644.9 -0.691 -1usable8 Ω vs 16 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 4.9 mm < 5.5 mm: lower excursion-limited SPL+
BMS 6S11780 +150.43 +0.0710.4 +0.55 -0.593 +1usable130 W vs 200 W: lower power handling · Xmax 5 mm < 5.5 mm: lower excursion-limited SPL+
LaVoce WAN061.8060 -50.27 -0.0911.18 +1.285.2 -0.393 +1usable8 Ω vs 16 Ω: amp load changes · Xmax 5.2 mm < 5.5 mm: lower excursion-limited SPL+
Sica 6 E 1.5 CS60 -50.38 +0.0211.3 +1.42.5 -391.5 -0.5usable8 Ω vs 16 Ω: amp load changes · 100 W vs 200 W: lower power handling · Xmax 2.5 mm < 5.5 mm: lower excursion-limited SPL+
Sica 6 L 1.5 SL59 -60.39 +0.0311 +1.12.5 -391 -1usable8 Ω vs 16 Ω: amp load changes · 130 W vs 200 W: lower power handling · Xmax 2.5 mm < 5.5 mm: lower excursion-limited SPL+
Sica 6 H 1.5 CP46 -190.35 -0.0116.6 +6.76 +0.589.4 -2.6usable8 Ω vs 16 Ω: amp load changes · 120 W vs 200 W: lower power handling+

Comparer les 3 plus proches avec le 6RS140 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.