← tous les HP

Faital PRO 6FE300

6" · 8 Ω · 175 W · 94 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale6"
Impédance8 Ω
Fs100 Hz
Qts0.46
Qes0.48
Qms10.5
Vas4.7 L
Sd138 cm²
Xmax3.9 mm
Re5.3 Ω
Mms14.2 g
Pe175 W
Sensibilité94 dB

Indication d'alignement

EBP208 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 3.4 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Faital PRO 6FE400100 =0.5 +0.045.5 +0.84.77 +0.8794 =close16 Ω vs 8 Ω: amp load changes+
Faital PRO 6FE30098 -20.41 -0.054.4 -0.33.9 =92 -2close4 Ω vs 8 Ω: amp load changes+
Eminence ALPHA 6C107 +70.45 -0.015.7 +13.5 -0.493.3 -0.7close4 Ω vs 8 Ω: amp load changes · 100 W vs 175 W: lower power handling · Xmax 3.5 mm < 3.9 mm: lower excursion-limited SPL+
LaVoce WSN061.52-16108 +80.53 +0.074.46 -0.243.7 -0.293 -1close16 Ω vs 8 Ω: amp load changes · 125 W vs 175 W: lower power handling · Xmax 3.7 mm < 3.9 mm: lower excursion-limited SPL+
Faital PRO 6FE400100 =0.36 -0.15 +0.34.77 +0.8794 =close+
Faital PRO 6FE400100 =0.36 -0.14.9 +0.24.87 +0.9793 -1close4 Ω vs 8 Ω: amp load changes+
Faital PRO 6FE200120 +200.42 -0.044.3 -0.44.62 +0.7295 +1usable4 Ω vs 8 Ω: amp load changes · 130 W vs 175 W: lower power handling+
Eminence ALPHA-6A103 +30.54 +0.085.8 +1.13.5 -0.493.6 -0.4usable100 W vs 175 W: lower power handling · Xmax 3.5 mm < 3.9 mm: lower excursion-limited SPL+
LaVoce WSN061.5290 -100.39 -0.075.92 +1.223.8 -0.194 =usable125 W vs 175 W: lower power handling · Xmax 3.8 mm < 3.9 mm: lower excursion-limited SPL+
LaVoce WSN061.52-490 -100.37 -0.095.15 +0.454 +0.192.5 -1.5usable4 Ω vs 8 Ω: amp load changes · 125 W vs 175 W: lower power handling+

Comparer les 3 plus proches avec le 6FE300 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.