Faital PRO 3FE26
Paramètres Thiele-Small
| Taille nominale | 3" |
|---|---|
| Impédance | 8 Ω |
| Fs | 150 Hz |
| Qts | 0.79 |
| Qes | 1.1 |
| Qms | 2.8 |
| Vas | 0.9 L |
| Sd | 33 cm² |
| Xmax | 2 mm |
| Re | 6.2 Ω |
| Mms | 1.9 g |
| Pe | 20 W |
| Sensibilité | 90 dB |
Indication d'alignement
| EBP | 136 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Faital PRO 3FE26 | 150 = | 1.08 +0.29 | 0.9 = | 2 = | 90 = | close | 16 Ω vs 8 Ω: amp load changes | + |
| Eminence ALPHA 3-32 | 117 -33 | 0.74 -0.05 | 0.98 +0.08 | 2.6 +0.6 | 88 -2 | usable | 32 Ω vs 8 Ω: amp load changes | + |
| Faital PRO 3FE25 | 110 -40 | 0.83 +0.04 | 1.3 +0.4 | 1.83 -0.17 | 90 = | usable | 16 Ω vs 8 Ω: amp load changes · Xmax 1.83 mm < 2 mm: lower excursion-limited SPL | + |
| Sica 3 L 0.8 SL | 145 -5 | 1.01 +0.22 | 0.8 -0.1 | 1.5 -0.5 | 86.4 -3.6 | usable | Xmax 1.5 mm < 2 mm: lower excursion-limited SPL | + |
| LaVoce WSF030.70 | 112 -38 | 0.61 -0.18 | 0.89 -0.01 | 3.3 +1.3 | 85.5 -4.5 | usable | + | |
| Faital PRO 3FE25 | 110 -40 | 0.66 -0.13 | 1.3 +0.4 | 1.83 -0.17 | 91 +1 | usable | Xmax 1.83 mm < 2 mm: lower excursion-limited SPL | + |
| Eminence ALPHA 3-8 | 118 -32 | 0.5 -0.29 | 0.95 +0.05 | 2.4 +0.4 | 88.6 -1.4 | usable | + | |
| Faital PRO 3FE22 | 110 -40 | 0.56 -0.23 | 1.4 +0.5 | 1.83 -0.17 | 91 +1 | risky | 16 Ω vs 8 Ω: amp load changes · Xmax 1.83 mm < 2 mm: lower excursion-limited SPL | + |
| Faital PRO 3FE25 | 110 -40 | 0.52 -0.27 | 1.3 +0.4 | 1.73 -0.27 | 91 +1 | risky | 4 Ω vs 8 Ω: amp load changes · Xmax 1.73 mm < 2 mm: lower excursion-limited SPL | + |
| Faital PRO 3FE22 | 110 -40 | 0.47 -0.32 | 1.3 +0.4 | 1.83 -0.17 | 91 +1 | risky | Xmax 1.83 mm < 2 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 3FE26 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.