Faital PRO 21XL3000

21" · 8 Ω · 3000 W · 98 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale21"
Impédance8 Ω
Fs30 Hz
Qts0.25
Qes0.25
Qms8.8
Vas284.6 L
Sd1744 cm²
Xmax17.67 mm
Re5.9 Ω
Mms420 g
Pe3000 W
Sensibilité98 dB

Indication d'alignement

EBP120 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 40.7 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Beyma 21"LEX1600/Nd30 =0.29 +0.04305 +20.414 -3.6798 =close1600 W vs 3000 W: lower power handling · Xmax 14 mm < 17.67 mm: lower excursion-limited SPL+
Beyma 21QLEX1600Fe30 =0.28 +0.03309 +24.413 -4.6798 =close1600 W vs 3000 W: lower power handling · Xmax 13 mm < 17.67 mm: lower excursion-limited SPL+
18 Sound 21NTLW500030 =0.32 +0.07300 +15.417.5 -0.1797 -1close4 Ω vs 8 Ω: amp load changes · 1800 W vs 3000 W: lower power handling · Xmax 17.5 mm < 17.67 mm: lower excursion-limited SPL+
Faital PRO 21XL300032 +20.22 -0.03223.5 -61.117.67 =98 =close4 Ω vs 8 Ω: amp load changes+
RCF LF21N45130 =0.26 +0.01375 +90.413 -4.6798.5 +0.5usable1500 W vs 3000 W: lower power handling · Xmax 13 mm < 17.67 mm: lower excursion-limited SPL+
18 Sound 21NLW530031 +10.32 +0.07325 +40.415.3 -2.3798.5 +0.5usable1800 W vs 3000 W: lower power handling · Xmax 15.3 mm < 17.67 mm: lower excursion-limited SPL+
Eminence NSW6021-629 -10.31 +0.06224.58 -60.0221 +3.3397 -1usable6 Ω vs 8 Ω: amp load changes+
18 Sound 21NTLW500031 +10.36 +0.11270 -14.617.5 -0.1797 -1usable1800 W vs 3000 W: lower power handling · Xmax 17.5 mm < 17.67 mm: lower excursion-limited SPL+
B&C 21DS11534 +40.27 +0.02204 -80.616.5 -1.1799 +1usable1700 W vs 3000 W: lower power handling · Xmax 16.5 mm < 17.67 mm: lower excursion-limited SPL+
18 Sound 21NLW900132 +20.31 +0.06244 -40.614 -3.6798 =usable1800 W vs 3000 W: lower power handling · Xmax 14 mm < 17.67 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 21XL3000 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.