Faital PRO 18FX600
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 32 Hz |
| Qts | 0.3 |
| Qes | 0.31 |
| Qms | 9.8 |
| Vas | 257.3 L |
| Sd | 1213 cm² |
| Xmax | 11.25 mm |
| Re | 5 Ω |
| Mms | 175 g |
| Pe | 700 W |
| Sensibilité | 99 dB |
Indication d'alignement
| EBP | 103 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 56.5 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| RCF LF18X401 | 30 -2 | 0.3 = | 274 +16.7 | 12 +0.75 | 97.5 -1.5 | close | + | |
| RCF LF18Y402 | 30 -2 | 0.3 = | 274 +16.7 | 12 +0.75 | 97.5 -1.5 | close | + | |
| RCF LF 18X401 | 30 -2 | 0.298 = | 274 +16.7 | 11.4 +0.15 | 97.5 -1.5 | close | + | |
| RCF LF18G401 | 33 +1 | 0.29 -0.01 | 268 +10.7 | 9 -2.25 | 98 -1 | close | Xmax 9 mm < 11.25 mm: lower excursion-limited SPL | + |
| RCF LF18G908 | 33 +1 | 0.29 -0.01 | 268 +10.7 | 9 -2.25 | 98 -1 | close | Xmax 9 mm < 11.25 mm: lower excursion-limited SPL | + |
| Peavey LO MAX 18 v2011 | 33.5 +1.5 | 0.321 +0.02 | 294.4 +37.1 | 10.2 -1.05 | 98.9 -0.1 | close | Xmax 10.2 mm < 11.25 mm: lower excursion-limited SPL | + |
| Peavey LO MAX 18 | 33.5 +1.5 | 0.318 +0.02 | 249.7 -7.6 | 9.5 -1.75 | 97.7 -1.3 | close | Xmax 9.5 mm < 11.25 mm: lower excursion-limited SPL | + |
| Faital PRO 18XL1600 | 32 = | 0.31 +0.01 | 201.1 -56.2 | 12.92 +1.67 | 98 -1 | close | 4 Ω vs 8 Ω: amp load changes | + |
| PHL Audio 7090 v2012 | 34 +2 | 0.297 = | 260 +2.7 | 7.9 -3.35 | 98.6 -0.4 | close | Xmax 7.9 mm < 11.25 mm: lower excursion-limited SPL | + |
| RCF LF 18G401 | 33 +1 | 0.289 -0.01 | 268 +10.7 | 8.2 -3.05 | 99.3 +0.3 | close | Xmax 8.2 mm < 11.25 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 18FX600 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.