Faital PRO 15FH520

15" · 16 Ω · 600 W · 97 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale15"
Impédance16 Ω
Fs42 Hz
Qts0.62
Qes0.65
Qms13.5
Vas134.2 L
Sd847 cm²
Xmax9 mm
Re12.7 Ω
Mms107.2 g
Pe600 W
Sensibilité97 dB

Indication d'alignement

EBP65 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 446.2 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Eminence DEFINIMAX 4015 LF42 =0.5 -0.12115.5 -18.79 =96 -1usable8 Ω vs 16 Ω: amp load changes+
P.Audio BM-15LF47 +50.668 +0.05123.4 -10.87.1 -1.996.5 -0.5usable8 Ω vs 16 Ω: amp load changes · Xmax 7.1 mm < 9 mm: lower excursion-limited SPL+
18 Sound 15TLW300042 =0.44 -0.18140 +5.89 =95.5 -1.5usable8 Ω vs 16 Ω: amp load changes+
Beyma 15MCS50046 +40.48 -0.14134 -0.28 -198 +1usable8 Ω vs 16 Ω: amp load changes · Xmax 8 mm < 9 mm: lower excursion-limited SPL+
SB Audience BIANCO-15OB35041 -10.697 +0.08134.8 +0.66.5 -2.593.4 -3.6usable8 Ω vs 16 Ω: amp load changes · 350 W vs 600 W: lower power handling · Xmax 6.5 mm < 9 mm: lower excursion-limited SPL+
Eminence KappaLITE 3015LF44 +20.46 -0.16150.9 +16.79.6 +0.698.4 +1.4usable8 Ω vs 16 Ω: amp load changes · 450 W vs 600 W: lower power handling+
Beyma 15MC50046 +40.45 -0.17134 -0.28 -198 +1usable8 Ω vs 16 Ω: amp load changes · Xmax 8 mm < 9 mm: lower excursion-limited SPL+
SB Audience BIANCO-15MW20044 +20.586 -0.03153 +18.85.2 -3.896 -1usable8 Ω vs 16 Ω: amp load changes · 200 W vs 600 W: lower power handling · Xmax 5.2 mm < 9 mm: lower excursion-limited SPL+
Ciare FXE 15-440.6 -1.40.406 -0.21131 -3.28.4 -0.696.5 -0.5usable8 Ω vs 16 Ω: amp load changes · Xmax 8.4 mm < 9 mm: lower excursion-limited SPL+
Beyma 15MCS500-846 +40.47 -0.15133.5 -0.76.5 -2.597.5 +0.5usable8 Ω vs 16 Ω: amp load changes · Xmax 6.5 mm < 9 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 15FH520 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.