Faital PRO 15FH500
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 35 Hz |
| Qts | 0.31 |
| Qes | 0.32 |
| Qms | 10.4 |
| Vas | 199.2 L |
| Sd | 847 cm² |
| Xmax | 9.25 mm |
| Re | 5.1 Ω |
| Mms | 104 g |
| Pe | 500 W |
| Sensibilité | 98 dB |
Indication d'alignement
| EBP | 109 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 47.4 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence KAPPA PRO 15 LF-2 | 35 = | 0.307 = | 198.8 -0.4 | 8.2 -1.05 | 97.1 -0.9 | close | Xmax 8.2 mm < 9.25 mm: lower excursion-limited SPL | + |
| Monacor SP-15/500FH | 35 = | 0.31 = | 218 +18.8 | 7.8 -1.45 | 98.6 +0.6 | close | Xmax 7.8 mm < 9.25 mm: lower excursion-limited SPL | + |
| Eminence KAPPA PRO 15 LF v2 | 35 = | 0.31 = | 172.5 -26.7 | 8.7 -0.55 | 96.8 -1.2 | close | Xmax 8.7 mm < 9.25 mm: lower excursion-limited SPL | + |
| Beyma 15LX60 | 35 = | 0.346 +0.04 | 215 +15.8 | 9 -0.25 | 97.7 -0.3 | close | Xmax 9 mm < 9.25 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH510 | 35 = | 0.26 -0.05 | 191.8 -7.4 | 9.25 = | 98 = | close | + | |
| Eminence Kappa Pro-15LF | 35 = | 0.3 -0.01 | 198.8 -0.4 | 6.7 -2.55 | 97.8 -0.2 | close | Xmax 6.7 mm < 9.25 mm: lower excursion-limited SPL | + |
| PD PDN 15BR40 | 35.7 +0.7 | 0.338 +0.03 | 224.8 +25.6 | 9.8 +0.55 | 98.5 +0.5 | close | + | |
| Precision Devices PDN 15BR40 | 35.7 +0.7 | 0.338 +0.03 | 224.8 +25.6 | 9.8 +0.55 | 98.5 +0.5 | close | + | |
| DAS Audio 15S | 35 = | 0.287 -0.02 | 188 -11.2 | 8 -1.25 | 97.4 -0.6 | close | Xmax 8 mm < 9.25 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH500 | 33 -2 | 0.28 -0.03 | 209.5 +10.3 | 9.45 +0.2 | 97 -1 | close | 4 Ω vs 8 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 15FH500 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.