← tous les HP

Faital PRO 12PR330

12" · 16 Ω · 300 W · 97 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance16 Ω
Fs52 Hz
Qts0.49
Qes0.53
Qms5.8
Vas76.3 L
Sd533 cm²
Xmax7.27 mm
Re11.3 Ω
Mms48.7 g
Pe300 W
Sensibilité97 dB

Indication d'alignement

EBP98 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 70.5 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Ciare HSB322-22 vp42.5 -9.50.484 -0.0177 +0.77.3 +0.0396.4 -0.6close4 Ω vs 16 Ω: amp load changes+
Beyma 12CMV352 =0.55 +0.0685 +8.77 -0.2796.5 -0.5close8 Ω vs 16 Ω: amp load changes · Xmax 7 mm < 7.27 mm: lower excursion-limited SPL+
Beyma 12CMV249 -30.47 -0.0276 -0.37 -0.2794 -3close8 Ω vs 16 Ω: amp load changes · Xmax 7 mm < 7.27 mm: lower excursion-limited SPL+
the box Speaker 12-280/8-A50.6 -1.40.472 -0.0272.8 -3.55.5 -1.7796.1 -0.9close8 Ω vs 16 Ω: amp load changes · Xmax 5.5 mm < 7.27 mm: lower excursion-limited SPL+
Elder Audio 12LB075-U50 -20.472 -0.0272.8 -3.55.5 -1.7796 -1close8 Ω vs 16 Ω: amp load changes · Xmax 5.5 mm < 7.27 mm: lower excursion-limited SPL+
Faital PRO 12PR33050 -20.4 -0.0979.1 +2.87.37 +0.198 +1close8 Ω vs 16 Ω: amp load changes+
Davis 31TCA12 vn251.8 -0.20.484 -0.0178.4 +2.14.6 -2.6796 -1close8 Ω vs 16 Ω: amp load changes · 200 W vs 300 W: lower power handling · Xmax 4.6 mm < 7.27 mm: lower excursion-limited SPL+
Davis 31TCA12 vp2015 n151.8 -0.20.484 -0.0178.4 +2.14.6 -2.6796 -1close8 Ω vs 16 Ω: amp load changes · 200 W vs 300 W: lower power handling · Xmax 4.6 mm < 7.27 mm: lower excursion-limited SPL+
Faital PRO 12FH52055 +30.47 -0.0256.4 -19.97 -0.2797 =closeXmax 7 mm < 7.27 mm: lower excursion-limited SPL+
Radian CRS123048 -40.464 -0.0376 -0.35.5 -1.7795.8 -1.2close8 Ω vs 16 Ω: amp load changes · Xmax 5.5 mm < 7.27 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 12PR330 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.