Faital PRO 12PR300-4
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 50 Hz |
| Qts | 0.392 |
| Qes | 0.4 |
| Qms | 19.4 |
| Vas | 63.1 L |
| Sd | 489 cm² |
| Xmax | 4.9 mm |
| Re | 3.3 Ω |
| Bl | 11.8 T·m |
| Mms | 53.8 g |
| Pe | 300 W |
| Sensibilité | 98.8 dB |
Indication d'alignement
| EBP | 125 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 28 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Faital PRO 12PR310-4 | 50 = | 0.417 +0.02 | 66.1 +3 | 4.9 = | 98.7 -0.1 | close | + | |
| Faital PRO 12PR310-8 | 54 +4 | 0.396 = | 62.8 -0.3 | 4.9 = | 97.5 -1.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| SB Audience BIANCO-12MW200 | 50 = | 0.389 = | 68.7 +5.6 | 6 +1.1 | 97.2 -1.6 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Faital PRO 12HX500 | 54 +4 | 0.396 = | 62.3 -0.8 | 5.5 +0.6 | 97.2 -1.6 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Fane COLOSSUS 12MBN | 55 +5 | 0.396 = | 63 -0.1 | 5.5 +0.6 | 97.4 -1.4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Fane 12-300 vp FRL | 50 = | 0.39 = | 62 -1.1 | 4.5 -0.4 | 96.2 -2.6 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 4.5 mm < 4.9 mm: lower excursion-limited SPL | + |
| Eminence DELTA 12 LFC | 52 +2 | 0.445 +0.05 | 63.7 +0.6 | 4.8 -0.1 | 98.8 = | close | Xmax 4.8 mm < 4.9 mm: lower excursion-limited SPL | + |
| Faital PRO 12PR310 | 54 +4 | 0.4 +0.01 | 73.5 +10.4 | 4.92 +0.02 | 99 +0.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Faital PRO 12PR300-8 | 54 +4 | 0.382 -0.01 | 73.5 +10.4 | 4.9 = | 98.2 -0.6 | close | 8 Ω vs 4 Ω: amp load changes | + |
| LaVoce WSN122.50-16 | 53 +3 | 0.4 +0.01 | 65.84 +2.74 | 4.6 -0.3 | 96.5 -2.3 | close | 16 Ω vs 4 Ω: amp load changes · Xmax 4.6 mm < 4.9 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 12PR300-4 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.