Faital PRO 12FH500
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 45 Hz |
| Qts | 0.25 |
| Qes | 0.26 |
| Qms | 6.9 |
| Vas | 87.3 L |
| Sd | 529 cm² |
| Xmax | 7.5 mm |
| Re | 5.1 Ω |
| Mms | 56 g |
| Pe | 500 W |
| Sensibilité | 97 dB |
Indication d'alignement
| EBP | 173 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 12.5 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Faital PRO 12FH510 | 45 = | 0.25 = | 75.2 -12.1 | 7.5 = | 97 = | close | 4 Ω vs 8 Ω: amp load changes | + |
| Faital PRO 12FH510 | 45 = | 0.24 -0.01 | 81.3 -6 | 7.5 = | 98 +1 | close | + | |
| Faital PRO 12FH530 | 45 = | 0.26 +0.01 | 74.1 -13.2 | 7.5 = | 98 +1 | close | + | |
| Beyma 12CXA400Nd v2018 | 45 = | 0.251 = | 88.5 +1.2 | 5.5 -2 | 97.7 +0.7 | close | Xmax 5.5 mm < 7.5 mm: lower excursion-limited SPL | + |
| RCF L 12P300 | 40 -5 | 0.242 -0.01 | 81 -6.3 | 7.8 +0.3 | 96.7 -0.3 | close | + | |
| Faital PRO 12FH500 | 45 = | 0.22 -0.03 | 80.3 -7 | 7.25 -0.25 | 97 = | close | 4 Ω vs 8 Ω: amp load changes · Xmax 7.25 mm < 7.5 mm: lower excursion-limited SPL | + |
| 18 Sound 12ND730 | 45 = | 0.23 -0.02 | 90 +2.7 | 6.5 -1 | 98 +1 | close | Xmax 6.5 mm < 7.5 mm: lower excursion-limited SPL | + |
| Monacor SP-12/500FH | 45 = | 0.251 = | 76.2 -11.1 | 6.4 -1.1 | 98.2 +1.2 | close | Xmax 6.4 mm < 7.5 mm: lower excursion-limited SPL | + |
| Beyma 12"WR400 | 42 -3 | 0.27 +0.02 | 91 +3.7 | 6.3 -1.2 | 97 = | close | Xmax 6.3 mm < 7.5 mm: lower excursion-limited SPL | + |
| Oberton 12B401 | 46.63 +1.63 | 0.245 -0.01 | 69.6 -17.7 | 6.75 -0.75 | 97 = | close | Xmax 6.75 mm < 7.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 12FH500 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.