← tous les HP

Faital PRO 12FE330

12" · 8 Ω · 250 W · 94 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance8 Ω
Fs33 Hz
Qts0.45
Qes0.48
Qms7
Vas146.7 L
Sd579 cm²
Xmax8.32 mm
Re5.3 Ω
Mms74.2 g
Pe250 W
Sensibilité94 dB

Indication d'alignement

EBP69 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 99.9 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Celestion PULSE XL 12.2035.1 +2.10.503 +0.05153.3 +6.68.3 -0.0294.2 +0.2closeXmax 8.3 mm < 8.32 mm: lower excursion-limited SPL+
Beyma 12"BR7031 -20.5 +0.05142 -4.78 -0.3293 -1close125 W vs 250 W: lower power handling · Xmax 8 mm < 8.32 mm: lower excursion-limited SPL+
JBL P120030 -30.45 =123 -23.77.8 -0.5292.8 -1.2closeXmax 7.8 mm < 8.32 mm: lower excursion-limited SPL+
Visaton W300-832 -10.449 =190 +43.37 -1.3293.4 -0.6close150 W vs 250 W: lower power handling · Xmax 7 mm < 8.32 mm: lower excursion-limited SPL+
Infinity 120W.IB32 -10.527 +0.08127 -19.78.1 -0.2294.9 +0.9close4 Ω vs 8 Ω: amp load changes · Xmax 8.1 mm < 8.32 mm: lower excursion-limited SPL+
JBL GT2-1229.5 -3.50.42 -0.03114.9 -31.88 -0.3294.1 +0.1usable4 Ω vs 8 Ω: amp load changes · Xmax 8 mm < 8.32 mm: lower excursion-limited SPL+
Infinity KAPPA CS 120 LB29 -40.485 +0.03161.4 +14.76.7 -1.6294.3 +0.3usable4 Ω vs 8 Ω: amp load changes · Xmax 6.7 mm < 8.32 mm: lower excursion-limited SPL+
McCauley 623235 +20.411 -0.04106.2 -40.58.4 +0.0893.6 -0.4usable+
MCM Electronics 55-298236.2 +3.20.407 -0.04121.7 -257 -1.3293.9 -0.1usableXmax 7 mm < 8.32 mm: lower excursion-limited SPL+
Beyma 12BR70 v201431 -20.497 +0.05142 -4.76 -2.3292.3 -1.7usable125 W vs 250 W: lower power handling · Xmax 6 mm < 8.32 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 12FE330 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.