← tous les HP

Faital PRO 10RS430 v2026

10" · 8 Ω · 400 W · 90.8 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance8 Ω
Fs32 Hz
Qts0.301
Qes0.31
Qms10
Vas61.5 L
Sd344 cm²
Xmax9.7 mm
Re6.8 Ω
Bl17.2 T·m
Mms66.7 g
Pe400 W
Sensibilité90.8 dB

Indication d'alignement

EBP103 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 13.6 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Faital PRO 10RS430 v202532 =0.282 -0.0259.2 -2.39.2 -0.590.9 +0.1closeXmax 9.2 mm < 9.7 mm: lower excursion-limited SPL+
Faital PRO 10RS43032 =0.28 -0.0259.2 -2.313.57 +3.8791 +0.2close+
Visaton TIW250XS 8 Ohms31 -10.298 =73 +11.58.1 -1.691.8 +1close200 W vs 400 W: lower power handling · Xmax 8.1 mm < 9.7 mm: lower excursion-limited SPL+
Visaton TIW250XS 8 Ohms v233 +10.328 +0.0366 +4.57.9 -1.891.8 +1close200 W vs 400 W: lower power handling · Xmax 7.9 mm < 9.7 mm: lower excursion-limited SPL+
Alpine SWG-104433 +10.34 +0.0465 +3.58 -1.789.8 -1close4 Ω vs 8 Ω: amp load changes · 150 W vs 400 W: lower power handling · Xmax 8 mm < 9.7 mm: lower excursion-limited SPL+
Kartesian SUB250_VHE v202226 -60.314 +0.0157.3 -4.29.3 -0.489.6 -1.2close300 W vs 400 W: lower power handling · Xmax 9.3 mm < 9.7 mm: lower excursion-limited SPL+
Audax HT240G428 -40.302 =67 +5.58 -1.793 +2.2usable4 Ω vs 8 Ω: amp load changes · 200 W vs 400 W: lower power handling · Xmax 8 mm < 9.7 mm: lower excursion-limited SPL+
Visaton TIW25031 -10.324 +0.0280 +18.58.8 -0.991.7 +0.9usable200 W vs 400 W: lower power handling · Xmax 8.8 mm < 9.7 mm: lower excursion-limited SPL+
Volt RV255028 -40.331 +0.0371.8 +10.39.1 -0.689.5 -1.3usable250 W vs 400 W: lower power handling · Xmax 9.1 mm < 9.7 mm: lower excursion-limited SPL+
AE Speakers TD10S32.7 +0.70.347 +0.0567.5 +67 -2.791.4 +0.6usableXmax 7 mm < 9.7 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 10RS430 v2026 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.