← tous les HP

Faital PRO 10FE400

10" · 4 Ω · 200 W · 95 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance4 Ω
Fs60 Hz
Qts0.41
Qes0.44
Qms5.2
Vas33.6 L
Sd362 cm²
Xmax5.62 mm
Re3.2 Ω
Mms38.3 g
Pe200 W
Sensibilité95 dB

Indication d'alignement

EBP136 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 17 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Faital PRO 10PR33060 =0.36 -0.0532.9 -0.77.27 +1.6595 =close16 Ω vs 4 Ω: amp load changes+
B&C 10CL5158 -20.38 -0.0336 +2.45.5 -0.1296 +1close8 Ω vs 4 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 5.5 mm < 5.62 mm: lower excursion-limited SPL+
Jensen SMOOTH BS 10N/250A58 -20.429 +0.0230.9 -2.74.7 -0.9295.1 +0.1close8 Ω vs 4 Ω: amp load changes · Xmax 4.7 mm < 5.62 mm: lower excursion-limited SPL+
Faital PRO 10FE40060 =0.47 +0.0635.3 +1.75.42 -0.296 +1close8 Ω vs 4 Ω: amp load changes · Xmax 5.42 mm < 5.62 mm: lower excursion-limited SPL+
Jensen BS10N/25058 -20.438 +0.0330.9 -2.74.8 -0.8295 =close8 Ω vs 4 Ω: amp load changes · Xmax 4.8 mm < 5.62 mm: lower excursion-limited SPL+
Jensen BS10N/250A58 -20.438 +0.0330.9 -2.74.8 -0.8295 =close8 Ω vs 4 Ω: amp load changes · Xmax 4.8 mm < 5.62 mm: lower excursion-limited SPL+
SICA PL10B25S57.6 -2.40.438 +0.0330.9 -2.74.8 -0.8294.9 -0.1close8 Ω vs 4 Ω: amp load changes · Xmax 4.8 mm < 5.62 mm: lower excursion-limited SPL+
18 Sound 10W65064 +40.41 =27 -6.65.7 +0.0896 +1close16 Ω vs 4 Ω: amp load changes+
LaVoce WSF102.0065 +50.45 +0.0434.03 +0.435.2 -0.4297 +2close8 Ω vs 4 Ω: amp load changes · Xmax 5.2 mm < 5.62 mm: lower excursion-limited SPL+
LaVoce FBASS10-1865 +50.43 +0.0232.4 -1.24.5 -1.1296 +1close8 Ω vs 4 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 4.5 mm < 5.62 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 10FE400 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.