EMS B15EX-07.5V
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 22 Hz |
| Qts | 0.228 |
| Qes | 0.236 |
| Qms | 7.16 |
| Vas | 791 L |
| Sd | 855 cm² |
| Xmax | 7 mm |
| Re | 6.54 Ω |
| Bl | 16.1 T·m |
| Mms | 67.8 g |
| Pe | 100 W |
| Sensibilité | 98.4 dB |
Indication d'alignement
| EBP | 93 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 91.8 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| EMS B15EX | 22 = | 0.223 -0.01 | 791 = | 7 = | 98.5 +0.1 | close | + | |
| Focal AUDIOM 15A | 21.5 -0.5 | 0.223 -0.01 | 832 +41 | 6 -1 | 98.8 +0.4 | close | Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| Supravox 400 GMF MK2 | 22 = | 0.206 -0.02 | 633 -158 | 7 = | 97.9 -0.5 | close | + | |
| Focal AUDIOM 15VX v2 | 18.4 -3.6 | 0.224 = | 727 -64 | 6 -1 | 96.1 -2.3 | usable | Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| Supravox 400-2000 vp2 | 21.1 -0.9 | 0.261 +0.03 | 715 -76 | 5 -2 | 96.8 -1.6 | usable | Xmax 5 mm < 7 mm: lower excursion-limited SPL | + |
| Supravox 400-2000 vp moy1 et 2 | 21.1 -0.9 | 0.273 +0.05 | 748 -43 | 5 -2 | 96.8 -1.6 | usable | Xmax 5 mm < 7 mm: lower excursion-limited SPL | + |
| Supravox 400-2000 vp1 | 21 -1 | 0.283 +0.05 | 780 -11 | 5 -2 | 96.8 -1.6 | usable | Xmax 5 mm < 7 mm: lower excursion-limited SPL | + |
| JBL 2215H | 20 -2 | 0.212 -0.02 | 736.2 -54.8 | 4.1 -2.9 | 97.7 -0.7 | usable | Xmax 4.1 mm < 7 mm: lower excursion-limited SPL | + |
| Fluxmag 1504B | 22.5 +0.5 | 0.224 = | 433.8 -357.2 | 7.3 +0.3 | 97 -1.4 | usable | + | |
| Usher Audio 1503HM | 21 -1 | 0.222 -0.01 | 528.8 -262.2 | 5.5 -1.5 | 97.2 -1.2 | usable | Xmax 5.5 mm < 7 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le B15EX-07.5V →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.