Eminence SWAMP THANG
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 97 Hz |
| Qts | 0.53 |
| Qes | 0.55 |
| Qms | 14.43 |
| Vas | 41.3 L |
| Sd | 532.4 cm² |
| Xmax | 0.8 mm |
| Re | 6.92 Ω |
| Bl | 14.1 T·m |
| Mms | 25.9 g |
| Pe | 150 W |
| Sensibilité | 101 dB |
Indication d'alignement
| EBP | 176 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 52.9 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence THE WIZARD | 89 -8 | 0.47 -0.06 | 41.5 +0.2 | 0.8 = | 100.9 -0.1 | close | 75 W vs 150 W: lower power handling | + |
| Eminence THE WIZARD 8 | 89 -8 | 0.47 -0.06 | 41.5 +0.2 | 0.8 = | 100.8 -0.2 | close | 75 W vs 150 W: lower power handling | + |
| Eminence CANNABIS REX | 96 -1 | 0.642 +0.11 | 45.5 +4.2 | 0.8 = | 100.5 -0.5 | close | 50 W vs 150 W: lower power handling | + |
| Eminence GA-SC64 | 88 -9 | 0.579 +0.05 | 45 +3.7 | 1.2 +0.4 | 99.3 -1.7 | close | 40 W vs 150 W: lower power handling | + |
| Eminence THE GOVERNOR 8 | 101 +4 | 0.561 +0.03 | 30.1 -11.2 | 1.2 +0.4 | 99.9 -1.1 | usable | 75 W vs 150 W: lower power handling | + |
| Eminence LEGEND GB128 | 86 -11 | 0.648 +0.12 | 43.9 +2.6 | 0.8 = | 99.2 -1.8 | usable | 50 W vs 150 W: lower power handling | + |
| Eminence THE TONKER 16 | 97 = | 0.581 +0.05 | 32.4 -8.9 | 0.8 = | 96.2 -4.8 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| Eminence CANIS MAJOR | 104.9 +7.9 | 0.664 +0.13 | 34.1 -7.2 | 0.8 = | 100.3 -0.7 | usable | 50 W vs 150 W: lower power handling | + |
| Jensen NEO 12 | 92 -5 | 0.705 +0.17 | 40.4 -0.9 | 1 +0.2 | 99 -2 | usable | 100 W vs 150 W: lower power handling | + |
| B&C 320K/C-A | 82 -15 | 0.5 -0.03 | 53 +11.7 | 2 +1.2 | 101 = | usable | + |
Comparer les 3 plus proches avec le SWAMP THANG →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.