Eminence OB A15 NEO
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 40.4 Hz |
| Qts | 0.723 |
| Qes | 0.83 |
| Qms | 5.59 |
| Vas | 234 L |
| Sd | 856.5 cm² |
| Xmax | 6 mm |
| Re | 6.28 Ω |
| Bl | 11.4 T·m |
| Mms | 68.2 g |
| Pe | 200 W |
| Sensibilité | 95.7 dB |
Indication d'alignement
| EBP | 49 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence FAS 154 | 38.3 -2.1 | 0.868 +0.15 | 211 -23 | 7.2 +1.2 | 96.2 +0.5 | close | 4 Ω vs 8 Ω: amp load changes | + |
| LaVoce LBASS15-15 | 37 -3.4 | 0.74 +0.02 | 284.84 +50.84 | 4.7 -1.3 | 96 +0.3 | usable | 100 W vs 200 W: lower power handling · Xmax 4.7 mm < 6 mm: lower excursion-limited SPL | + |
| Selenium 38GPT12 | 42.2 +1.8 | 0.657 -0.07 | 185.7 -48.3 | 5 -1 | 95.8 +0.1 | usable | Xmax 5 mm < 6 mm: lower excursion-limited SPL | + |
| Eminence DELTA 15 LF | 41 +0.6 | 0.584 -0.14 | 186.1 -47.9 | 6 = | 96 +0.3 | usable | + | |
| Fane 15-400LF | 39 -1.4 | 0.577 -0.15 | 210 -24 | 5 -1 | 96.1 +0.4 | usable | Xmax 5 mm < 6 mm: lower excursion-limited SPL | + |
| Fane 15-400LF v2016 | 41 +0.6 | 0.573 -0.15 | 210 -24 | 5 -1 | 97.1 +1.4 | usable | Xmax 5 mm < 6 mm: lower excursion-limited SPL | + |
| Fane SOVEREIGN 15-400 LF | 41 +0.6 | 0.573 -0.15 | 210 -24 | 5 -1 | 97.1 +1.4 | usable | Xmax 5 mm < 6 mm: lower excursion-limited SPL | + |
| Eminence DELTA 15LF-4 | 40 -0.4 | 0.49 -0.23 | 253.93 +19.93 | 5.97 -0.03 | 95 -0.7 | usable | 4 Ω vs 8 Ω: amp load changes · Xmax 5.97 mm < 6 mm: lower excursion-limited SPL | + |
| Selenium 15PW4 | 38 -2.4 | 0.752 +0.03 | 220.7 -13.3 | 3 -3 | 95 -0.7 | usable | Xmax 3 mm < 6 mm: lower excursion-limited SPL | + |
| SB Audience BIANCO-15OB350 | 41 +0.6 | 0.697 -0.03 | 134.8 -99.2 | 6.5 +0.5 | 93.4 -2.3 | usable | + |
Comparer les 3 plus proches avec le OB A15 NEO →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.