Eminence MME 2008 LF
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 36.4 Hz |
| Qts | 0.482 |
| Qes | 0.5 |
| Qms | 13.39 |
| Vas | 131.9 L |
| Sd | 532.4 cm² |
| Xmax | 3.7 mm |
| Re | 7.56 Ω |
| Bl | 14.1 T·m |
| Mms | 57.7 g |
| Pe | 200 W |
| Sensibilité | 93.3 dB |
Indication d'alignement
| EBP | 73 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 114.5 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence ME12/200LF | 36.4 = | 0.482 = | 131.9 = | 3.7 = | 93.3 = | close | + | |
| Visaton BZ300 4 Ohms | 36 -0.4 | 0.483 = | 129 -2.9 | 5 +1.3 | 95.7 +2.4 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Monacor SP-305I | 40 +3.6 | 0.48 = | 118 -13.9 | 4 +0.3 | 93.6 +0.3 | close | + | |
| MCM Electronics 55-2973 | 42 +5.6 | 0.481 = | 122.6 -9.3 | 5 +1.3 | 94.5 +1.2 | close | 120 W vs 200 W: lower power handling | + |
| Audax LFP501 | 40 +3.6 | 0.521 +0.04 | 138 +6.1 | 4.5 +0.8 | 94.6 +1.3 | close | 150 W vs 200 W: lower power handling | + |
| Audax PR30ST100 | 40 +3.6 | 0.521 +0.04 | 138 +6.1 | 4.5 +0.8 | 94.6 +1.3 | close | 100 W vs 200 W: lower power handling | + |
| MCM Electronics 55-3212 | 38.5 +2.1 | 0.477 -0.01 | 122.6 -9.3 | 4.7 +1 | 96.6 +3.3 | close | 4 Ω vs 8 Ω: amp load changes · 100 W vs 200 W: lower power handling | + |
| Conrad PA 12 | 42.9 +6.5 | 0.462 -0.02 | 129.2 -2.7 | 4 +0.3 | 95.2 +1.9 | close | + | |
| LaVoce LBASS12-15 | 38 +1.6 | 0.48 = | 160.93 +29.03 | 4.7 +1 | 95.5 +2.2 | close | 100 W vs 200 W: lower power handling | + |
| Monacor SP-304PA | 35.8 -0.6 | 0.519 +0.04 | 117 -14.9 | 3.3 -0.4 | 95 +1.7 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 3.3 mm < 3.7 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le MME 2008 LF →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.