Eminence MAGNUM 15 LF
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 37 Hz |
| Qts | 0.457 |
| Qes | 0.48 |
| Qms | 9.45 |
| Vas | 163 L |
| Sd | 856 cm² |
| Xmax | 7.9 mm |
| Re | 4.95 Ω |
| Bl | 16.7 T·m |
| Mms | 116.6 g |
| Pe | 700 W |
| Sensibilité | 96.4 dB |
Indication d'alignement
| EBP | 77 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 116.9 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| JBL 2216Nd vp | 36 -1 | 0.429 -0.03 | 166.8 +3.8 | 8.1 +0.2 | 95.9 -0.5 | close | + | |
| BMS 15N630 v2015 | 39 +2 | 0.422 -0.04 | 152 -11 | 7.8 -0.1 | 96.2 -0.2 | close | Xmax 7.8 mm < 7.9 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH520 v2018 | 38 +1 | 0.394 -0.06 | 156.6 -6.4 | 8.5 +0.6 | 96.7 +0.3 | close | + | |
| JBL 2216Nd | 36 -1 | 0.444 -0.01 | 140.7 -22.3 | 7.6 -0.3 | 95.1 -1.3 | close | Xmax 7.6 mm < 7.9 mm: lower excursion-limited SPL | + |
| BMS 15N630 | 39 +2 | 0.42 -0.04 | 152 -11 | 8 +0.1 | 98 +1.6 | close | + | |
| Sica 15 PFS 3 | 39 +2 | 0.45 -0.01 | 135.5 -27.5 | 7 -0.9 | 95.9 -0.5 | close | 500 W vs 700 W: lower power handling · Xmax 7 mm < 7.9 mm: lower excursion-limited SPL | + |
| Eminence OMEGA PRO-15-2KW-8 | 39.67 +2.67 | 0.44 -0.02 | 142.51 -20.49 | 7.4 -0.5 | 94.9 -1.5 | close | Xmax 7.4 mm < 7.9 mm: lower excursion-limited SPL | + |
| Kartesian WOM380_vTLHP-8 | 36 -1 | 0.39 -0.07 | 156.6 -6.4 | 7 -0.9 | 96.8 +0.4 | close | 400 W vs 700 W: lower power handling · Xmax 7 mm < 7.9 mm: lower excursion-limited SPL | + |
| 18 Sound 15W750 | 40 +3 | 0.42 -0.04 | 182 +19 | 8 +0.1 | 98 +1.6 | close | 16 Ω vs 8 Ω: amp load changes | + |
| Faital PRO 15FH520 v2025 | 36 -1 | 0.394 -0.06 | 186.5 +23.5 | 8.8 +0.9 | 96.8 +0.4 | close | + |
Comparer les 3 plus proches avec le MAGNUM 15 LF →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.