Eminence LEGEND B810

10" · 32 Ω · 150 W · 88 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance32 Ω
Fs52.1 Hz
Qts0.648
Qes0.68
Qms13.91
Vas66.4 L
Sd350.1 cm²
Xmax4.7 mm
Re27.5 Ω
Bl17.9 T·m
Mms24.2 g
Pe150 W
Sensibilité88 dB

Indication d'alignement

EBP77 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 348.1 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Fane 10-12555 +2.90.638 -0.0150.6 -15.84.7 =93.6 +5.6usable8 Ω vs 32 Ω: amp load changes+
Faital PRO 10FE20055 +2.90.69 +0.0461.7 -4.74.67 -0.0396 +8usable8 Ω vs 32 Ω: amp load changes · Xmax 4.67 mm < 4.7 mm: lower excursion-limited SPL+
Europsonic HP20/150C45 -7.10.75 +0.175 +8.64.4 -0.390.3 +2.3usable16 Ω vs 32 Ω: amp load changes · 75 W vs 150 W: lower power handling · Xmax 4.4 mm < 4.7 mm: lower excursion-limited SPL+
Fane SOVEREIGN 10-125 v255 +2.90.638 -0.0150 -16.44.6 -0.193.5 +5.5usable8 Ω vs 32 Ω: amp load changes · Xmax 4.6 mm < 4.7 mm: lower excursion-limited SPL+
Monacor SP-250PA v201748 -4.10.779 +0.1372 +5.64.3 -0.491.7 +3.7usable8 Ω vs 32 Ω: amp load changes · Xmax 4.3 mm < 4.7 mm: lower excursion-limited SPL+
Faital PRO 10FE200 v201455 +2.90.695 +0.0553.4 -134.7 =94.1 +6.1usable8 Ω vs 32 Ω: amp load changes+
Skytronic 902.21434.3 -17.80.595 -0.0570.2 +3.86.1 +1.487.7 -0.3usable8 Ω vs 32 Ω: amp load changes+
Sphynx SP-W250-PP43 -9.10.794 +0.1565.8 -0.64 -0.790.1 +2.1usable8 Ω vs 32 Ω: amp load changes · 80 W vs 150 W: lower power handling · Xmax 4 mm < 4.7 mm: lower excursion-limited SPL+
Focal 10P08 vp43.2 -8.90.56 -0.0965 -1.45.5 +0.893.9 +5.9usable8 Ω vs 32 Ω: amp load changes · 80 W vs 150 W: lower power handling+
GRS 10SW-434 -18.10.634 -0.0157.5 -8.96.3 +1.689.5 +1.5usable8 Ω vs 32 Ω: amp load changes+

Comparer les 3 plus proches avec le LEGEND B810 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.