Eminence KL3012CX-8
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 42 Hz |
| Qts | 0.299 |
| Qes | 0.31 |
| Qms | 8.37 |
| Vas | 111.5 L |
| Sd | 545.4 cm² |
| Xmax | 3.7 mm |
| Re | 5.7 Ω |
| Bl | 16.1 T·m |
| Mms | 53.7 g |
| Pe | 400 W |
| Sensibilité | 97.7 dB |
Indication d'alignement
| EBP | 135 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 24.3 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Supravox 285 GMF vp richard | 40 -2 | 0.298 = | 108 -3.5 | 3.7 = | 97.1 -0.6 | close | 70 W vs 400 W: lower power handling | + |
| Selenium 12PW5 | 43 +1 | 0.314 +0.02 | 108 -3.5 | 3.7 = | 97.5 -0.2 | close | 300 W vs 400 W: lower power handling | + |
| PHL Audio 4510 | 42 = | 0.307 +0.01 | 108 -3.5 | 6 +2.3 | 97.3 -0.4 | close | 300 W vs 400 W: lower power handling | + |
| PHL Audio 4550 | 45 +3 | 0.289 -0.01 | 106 -5.5 | 4 +0.3 | 98.3 +0.6 | close | 250 W vs 400 W: lower power handling | + |
| Beyma SM112-N2 | 40 -2 | 0.298 = | 117.3 +5.8 | 5.9 +2.2 | 96.9 -0.8 | close | 250 W vs 400 W: lower power handling | + |
| Fane SOVEREIGN PRO 12-500 | 43 +1 | 0.314 +0.02 | 107 -4.5 | 6 +2.3 | 97.4 -0.3 | close | + | |
| Monacor SP-12/200PA | 45 +3 | 0.328 +0.03 | 114 +2.5 | 4 +0.3 | 97.4 -0.3 | close | 200 W vs 400 W: lower power handling | + |
| Beyma SM112/N v2021 | 40 -2 | 0.298 = | 117 +5.5 | 7 +3.3 | 96.9 -0.8 | close | + | |
| PHL Audio 4500 | 42 = | 0.274 -0.02 | 108 -3.5 | 5.7 +2 | 99 +1.3 | close | 300 W vs 400 W: lower power handling | + |
| Beyma 12G125 | 41 -1 | 0.269 -0.03 | 122 +10.5 | 4 +0.3 | 97.2 -0.5 | close | 125 W vs 400 W: lower power handling | + |
Comparer les 3 plus proches avec le KL3012CX-8 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.