← tous les HP

Eminence KAPPALITE 3010 MB

10" · 8 Ω · 400 W · 99.1 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance8 Ω
Fs50.7 Hz
Qts0.204
Qes0.21
Qms6.83
Vas52.1 L
Sd366.1 cm²
Xmax5 mm
Re5.01 Ω
Bl16.4 T·m
Mms35.6 g
Pe400 W
Sensibilité99.1 dB

Indication d'alignement

EBP241 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 4.7 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Beyma 10"MI10050 -0.70.21 +0.0154 +1.94.5 -0.598 -1.1closeXmax 4.5 mm < 5 mm: lower excursion-limited SPL+
Beyma 10MI100 v201750 -0.70.213 +0.0154 +1.94.5 -0.597.9 -1.2closeXmax 4.5 mm < 5 mm: lower excursion-limited SPL+
Faital PRO 10PR30050 -0.70.24 +0.0449.8 -2.34.92 -0.0896 -3.1close4 Ω vs 8 Ω: amp load changes · 300 W vs 400 W: lower power handling · Xmax 4.92 mm < 5 mm: lower excursion-limited SPL+
Beyma 10M25050 -0.70.214 +0.0164 +11.93.5 -1.599 -0.1usable250 W vs 400 W: lower power handling · Xmax 3.5 mm < 5 mm: lower excursion-limited SPL+
Eminence Kappa Pro-10A46 -4.70.2 =52.2 +0.13.2 -1.897 -2.1usableXmax 3.2 mm < 5 mm: lower excursion-limited SPL+
Dayton Audio APOLLO 10N54 +3.30.222 +0.0243.5 -8.64.3 -0.797.1 -2usable250 W vs 400 W: lower power handling · Xmax 4.3 mm < 5 mm: lower excursion-limited SPL+
Eminence KAPPA PRO 1046 -4.70.196 -0.0152.2 +0.13.2 -1.896.9 -2.2usableXmax 3.2 mm < 5 mm: lower excursion-limited SPL+
Eminence KAPPA PRO 10 A46 -4.70.196 -0.0152.2 +0.13.2 -1.896.9 -2.2usableXmax 3.2 mm < 5 mm: lower excursion-limited SPL+
David Eden EC1060XL849.6 -1.10.207 =55.5 +3.42.4 -2.698.8 -0.3usable150 W vs 400 W: lower power handling · Xmax 2.4 mm < 5 mm: lower excursion-limited SPL+
SICA 10 FE 2.5 CP 4 Ohms51 +0.30.301 +0.147.7 -4.45.7 +0.799.1 =usable4 Ω vs 8 Ω: amp load changes · 300 W vs 400 W: lower power handling+

Comparer les 3 plus proches avec le KAPPALITE 3010 MB →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.