Eminence DELTALITE II 2510 (prodance)
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 53.4 Hz |
| Qts | 0.384 |
| Qes | 0.41 |
| Qms | 6.01 |
| Vas | 50.9 L |
| Sd | 346.4 cm² |
| Xmax | 4.2 mm |
| Re | 4.86 Ω |
| Bl | 10.8 T·m |
| Mms | 29.3 g |
| Pe | 250 W |
| Sensibilité | 96.9 dB |
Indication d'alignement
| EBP | 130 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 21.3 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| B&C 10 HPL 51 | 55 +1.6 | 0.367 -0.02 | 50 -0.9 | 4 -0.2 | 97.1 +0.2 | close | 150 W vs 250 W: lower power handling · Xmax 4 mm < 4.2 mm: lower excursion-limited SPL | + |
| Eminence DELTALITE II 2510 | 53 -0.4 | 0.417 +0.03 | 52.5 +1.6 | 4.2 = | 96.4 -0.5 | close | + | |
| Eminence DELTALITE II 2510-4 | 55 +1.6 | 0.381 = | 54.5 +3.6 | 4.2 = | 99.2 +2.3 | close | 4 Ω vs 8 Ω: amp load changes | + |
| SICA 10 C 2 CP | 54 +0.6 | 0.339 -0.04 | 53.6 +2.7 | 4 -0.2 | 96.6 -0.3 | close | 150 W vs 250 W: lower power handling · Xmax 4 mm < 4.2 mm: lower excursion-limited SPL | + |
| Faital PRO 10PR320 | 50 -3.4 | 0.38 = | 50.6 -0.3 | 7.27 +3.07 | 95 -1.9 | close | 16 Ω vs 8 Ω: amp load changes | + |
| Faital PRO 10FE300 | 50 -3.4 | 0.39 +0.01 | 49 -1.9 | 5.47 +1.27 | 94 -2.9 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Volt BM251.3 PA | 55 +1.6 | 0.346 -0.04 | 44 -6.9 | 4.8 +0.6 | 96.8 -0.1 | close | + | |
| LaVoce NBASS10-20 | 52 -1.4 | 0.39 +0.01 | 43.38 -7.52 | 6.6 +2.4 | 95.5 -1.4 | close | 150 W vs 250 W: lower power handling | + |
| Beyma 10CX25 | 53 -0.4 | 0.366 -0.02 | 66 +15.1 | 5 +0.8 | 97.1 +0.2 | close | + | |
| SICA 10 FE 2 CP | 55.7 +2.3 | 0.415 +0.03 | 45.9 -5 | 4 -0.2 | 95.5 -1.4 | close | 150 W vs 250 W: lower power handling · Xmax 4 mm < 4.2 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le DELTALITE II 2510 (prodance) →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.