Eminence DELTA PRO 18 A
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 26 Hz |
| Qts | 0.32 |
| Qes | 0.33 |
| Qms | 10.38 |
| Vas | 493.2 L |
| Sd | 1188 cm² |
| Xmax | 6.7 mm |
| Re | 5.3 Ω |
| Bl | 19.9 T·m |
| Mms | 150.3 g |
| Pe | 500 W |
| Sensibilité | 98 dB |
Indication d'alignement
| EBP | 79 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 127 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence DELTA PRO 18 | 26 = | 0.301 -0.02 | 523 +29.8 | 6.7 = | 98.4 +0.4 | close | + | |
| Eminence SIGMA PRO 18 (prodance) | 26 = | 0.301 -0.02 | 523 +29.8 | 6.1 -0.6 | 98.4 +0.4 | close | Xmax 6.1 mm < 6.7 mm: lower excursion-limited SPL | + |
| Eminence DELTA PRO 18 (Prodance) | 26.6 +0.6 | 0.301 -0.02 | 533.6 +40.4 | 6.7 = | 98.8 +0.8 | close | + | |
| Beyma 18LX60 | 27 +1 | 0.368 +0.05 | 500 +6.8 | 9 +2.3 | 97.7 -0.3 | close | + | |
| Eminence JAY7010 | 28.1 +2.1 | 0.314 -0.01 | 546.6 +53.4 | 9.1 +2.4 | 99.2 +1.2 | close | + | |
| Faital PRO 18FH500 | 28 +2 | 0.29 -0.03 | 456.7 -36.5 | 9.45 +2.75 | 98 = | close | 4 Ω vs 8 Ω: amp load changes | + |
| Eminence KAPPA 18 | 28 +2 | 0.32 = | 493.2 = | 4.8 -1.9 | 98.9 +0.9 | close | Xmax 4.8 mm < 6.7 mm: lower excursion-limited SPL | + |
| Eminence SIGMA PRO 18 A2 (prodance) | 26 = | 0.299 -0.02 | 613 +119.8 | 6.1 -0.6 | 98.3 +0.3 | close | Xmax 6.1 mm < 6.7 mm: lower excursion-limited SPL | + |
| MCM Electronics 55-2964 | 27 +1 | 0.313 -0.01 | 630.6 +137.4 | 6 -0.7 | 98.1 +0.1 | close | 300 W vs 500 W: lower power handling · Xmax 6 mm < 6.7 mm: lower excursion-limited SPL | + |
| Eminence SIGMA PRO 18 | 28 +2 | 0.29 -0.03 | 441.2 -52 | 6.1 -0.6 | 98.1 +0.1 | close | Xmax 6.1 mm < 6.7 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le DELTA PRO 18 A →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.