Eminence DELTALITE 2512 |
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 53.1 Hz |
| Qts | 0.52 |
| Qes | 0.64 |
| Qms | 2.94 |
| Vas | 67.44 L |
| Sd | 519.5 cm² |
| Xmax | 4.9 mm |
| Re | 5.28 Ω |
| Bl | 11.6 T·m |
| Mms | 48.58 g |
| Pe | 250 W |
| Sensibilité | 99.6 dB |
Indication d'alignement
| EBP | 83 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 79.4 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Faital PRO 12FE400 | 55 +1.9 | 0.52 = | 69.1 +1.66 | 5.42 +0.52 | 95 -4.6 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Eminence DELTA 12 LFC | 52 -1.1 | 0.445 -0.08 | 63.7 -3.74 | 4.8 -0.1 | 98.8 -0.8 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 4.8 mm < 4.9 mm: lower excursion-limited SPL | + |
| Eminence DELTA 12 LFA | 51 -2.1 | 0.477 -0.04 | 67.9 +0.46 | 4.8 -0.1 | 95.7 -3.9 | close | Xmax 4.8 mm < 4.9 mm: lower excursion-limited SPL | + |
| Faital PRO 12FE400 | 55 +1.9 | 0.57 +0.05 | 73.6 +6.16 | 5.42 +0.52 | 97 -2.6 | close | + | |
| Fane 12-500LF | 50 -3.1 | 0.495 -0.03 | 66 -1.44 | 5.5 +0.6 | 95.2 -4.4 | close | + | |
| Fane SOVEREIGN 12-500LF | 50 -3.1 | 0.495 -0.03 | 66 -1.44 | 5.5 +0.6 | 95.2 -4.4 | close | + | |
| Eminence DELTA 12 LF v2 | 51 -2.1 | 0.477 -0.04 | 67.9 +0.46 | 4.6 -0.3 | 95.7 -3.9 | close | Xmax 4.6 mm < 4.9 mm: lower excursion-limited SPL | + |
| Faital PRO 12PR330 | 52 -1.1 | 0.49 -0.03 | 76.3 +8.86 | 7.27 +2.37 | 97 -2.6 | close | 16 Ω vs 8 Ω: amp load changes | + |
| B&C 12 CLX 64 | 54 +0.9 | 0.575 +0.05 | 74 +6.56 | 5.3 +0.4 | 96.3 -3.3 | close | + | |
| Faital PRO 12PR310-4 | 50 -3.1 | 0.417 -0.1 | 66.1 -1.34 | 4.9 = | 98.7 -0.9 | close | 4 Ω vs 8 Ω: amp load changes | + |
Comparer les 3 plus proches avec le DELTALITE 2512 | →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.